Literature DB >> 28800389

Silicon Micropore-Based Parallel Plate Membrane Oxygenator.

Ajay Dharia1, Emily Abada2, Benjamin Feinberg2, Torin Yeager2, Willieford Moses3, Jaehyun Park2, Charles Blaha2, Nathan Wright2, Benjamin Padilla3, Shuvo Roy2.   

Abstract

Extracorporeal membrane oxygenation (ECMO) is a life support system that circulates the blood through an oxygenating system to temporarily (days to months) support heart or lung function during cardiopulmonary failure until organ recovery or replacement. Currently, the need for high levels of systemic anticoagulation and the risk for bleeding are main drawbacks of ECMO that can be addressed with a redesigned ECMO system. Our lab has developed an approach using microelectromechanical systems (MEMS) fabrication techniques to create novel gas exchange membranes consisting of a rigid silicon micropore membrane (SμM) support structure bonded to a thin film of gas-permeable polydimethylsiloxane (PDMS). This study details the fabrication process to create silicon membranes with highly uniform micropores that have a high level of pattern fidelity. The oxygen transport across these membranes was tested in a simple water-based bench-top set-up as well in a porcine in vivo model. It was determined that the mass transfer coefficient for the system using SµM-PDMS membranes was 3.03 ± 0.42 mL O2 min-1 m-2 cm Hg-1 with pure water and 1.71 ± 1.03 mL O2 min-1 m-2 cm Hg-1 with blood. An analytic model to predict gas transport was developed using data from the bench-top experiments and validated with in vivo testing. This was a proof of concept study showing adequate oxygen transport across a parallel plate SµM-PDMS membrane when used as a membrane oxygenator. This work establishes the tools and the equipoise to develop future generations of silicon micropore membrane oxygenators.
© 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  -Artificial lung; -Heart lung bypass; -Respiratory assist device; -Silicon micropore membrane; Extracorporeal membrane oxygenator

Mesh:

Substances:

Year:  2017        PMID: 28800389      PMCID: PMC5808906          DOI: 10.1111/aor.12972

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  11 in total

1.  Efficient gas-liquid contact using microfluidic membrane devices with staggered herringbone mixers.

Authors:  Tim Femmer; Max L Eggersdorfer; Alexander J C Kuehne; Matthias Wessling
Journal:  Lab Chip       Date:  2015-08-07       Impact factor: 6.799

Review 2.  Extracorporeal membrane oxygenation in the adult: a review of anticoagulation monitoring and transfusion.

Authors:  Stephen A Esper; Jerrold H Levy; Jonathan H Waters; Ian J Welsby
Journal:  Anesth Analg       Date:  2014-04       Impact factor: 5.108

3.  A mathematical model of gas exchange in an intravenous membrane oxygenator.

Authors:  T J Hewitt; B G Hattler; W J Federspiel
Journal:  Ann Biomed Eng       Date:  1998 Jan-Feb       Impact factor: 3.934

4.  Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy.

Authors:  Steven Kim; James Heller; Zohora Iqbal; Rishi Kant; Eun Jung Kim; Jeremy Durack; Maythem Saeed; Loi Do; Steven Hetts; Mark Wilson; Paul Brakeman; William H Fissell; Shuvo Roy
Journal:  ASAIO J       Date:  2016 Mar-Apr       Impact factor: 2.872

5.  The diffusion of oxygen, carbon dioxide, and inert gas in flowing blood.

Authors:  E E Spaeth; S K Friedlander
Journal:  Biophys J       Date:  2008-12-31       Impact factor: 4.033

6.  Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators.

Authors:  S N Vaslef; L F Mockros; R W Anderson; R J Leonard
Journal:  ASAIO J       Date:  1994 Oct-Dec       Impact factor: 2.872

Review 7.  The promise of microfluidic artificial lungs.

Authors:  Joseph A Potkay
Journal:  Lab Chip       Date:  2014-11-07       Impact factor: 6.799

8.  Extracorporeal Life Support Organization Registry Report 2012.

Authors:  Matthew L Paden; Steven A Conrad; Peter T Rycus; Ravi R Thiagarajan
Journal:  ASAIO J       Date:  2013 May-Jun       Impact factor: 2.872

9.  Increased trend in extracorporeal membrane oxygenation use by adults in the United States since 2007.

Authors:  Alicia K Gerke; Fan Tang; Joseph E Cavanaugh; Kevin C Doerschug; Philip M Polgreen
Journal:  BMC Res Notes       Date:  2015-11-18

Review 10.  Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.

Authors:  Julie-Ann Collins; Aram Rudenski; John Gibson; Luke Howard; Ronan O'Driscoll
Journal:  Breathe (Sheff)       Date:  2015-09
View more
  1 in total

Review 1.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.