Literature DB >> 18394051

History of hemodialyzers' designs.

Zbylut J Twardowski1.   

Abstract

Accumulation of knowledge requisite for development of hemodialysis started in antiquity and continued through Middle Ages until the 20th century. Firstly, it was determined that the kidneys produce urine containing toxic substances that accumulate in the body if the kidneys fail to function properly; secondly, it was necessary to discover the process of diffusion and dialysis; thirdly, it was necessary to develop a safe method to prevent clotting in the extracorporeal circulation; and fourthly, it was necessary to develop biocompatible dialyzing membranes. Most of the essential knowledge was acquired by the end of the 19th century. Hemodialysis as a practical means of replacing kidney function started and developed in the 20th century. The original hemodialyzers, using celloidin as a dialyzing membrane and hirudin as an anticoagulant, were used in animal experiments at the beginning of the 20th century, and then there were a few attempts in humans in the 1920s. Rapid progress started with the application of cellophane membranes and heparin as an anticoagulant in the late 1930s and 1940s. The explosion of new dialyzer designs continued in the 1950s and 1960s and ended with the development of capillary dialyzers. Cellophane was replaced by other dialyzing membranes in the 1960s, 1970s, and 1980s. Dialysis solution was originally prepared in the tank from water, electrolytes, and glucose. This solution was recirculated through the dialyzer and back to the tank. In the 1960s, a method of single-pass dialysis solution preparation and delivery system was designed. A large quantity of dialysis solution was used for a single dialysis. Sorbent systems, using a small volume of regenerated dialysis solution, were developed in the mid 1960s, and continue to be used for home hemodialysis and acute renal failure. At the end of the 20th century, a new closed system, which prepared and delivered ultrapure dialysis solution preparation, was developed. This system also had automatic reuse of lines and dialyzers and prepared the machine for the next dialysis. This was specifically designed for quotidian home hemodialysis. Another system for frequent home hemodialysis or acute renal failure was developed at the turn of the 21st century. This system used premanufactured dialysis solution, delivered to the home or dialysis unit, as is done for peritoneal dialysis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18394051     DOI: 10.1111/j.1542-4758.2008.00253.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  9 in total

Review 1.  Enhancing dialyser clearance-from target to development.

Authors:  Kamonwan Tangvoraphonkchai; Andrew Davenport
Journal:  Pediatr Nephrol       Date:  2017-04-12       Impact factor: 3.714

2.  Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy.

Authors:  Steven Kim; James Heller; Zohora Iqbal; Rishi Kant; Eun Jung Kim; Jeremy Durack; Maythem Saeed; Loi Do; Steven Hetts; Mark Wilson; Paul Brakeman; William H Fissell; Shuvo Roy
Journal:  ASAIO J       Date:  2016 Mar-Apr       Impact factor: 2.872

Review 3.  [Poison in the filter: implementing detoxification procedures in schizophrenia].

Authors:  Ekkehardt Kumbier
Journal:  Nervenarzt       Date:  2019-11       Impact factor: 1.214

4.  Single Lumen Alternating Micro-Batch Hemodiafiltration (SLAMB-HDF): A Device for Minimally Invasive Renal Replacement Therapy.

Authors:  Lakhmir S Chawla
Journal:  Kidney360       Date:  2020-07-31

5.  Diffusive Silicon Nanopore Membranes for Hemodialysis Applications.

Authors:  Steven Kim; Benjamin Feinberg; Rishi Kant; Benjamin Chui; Ken Goldman; Jaehyun Park; Willieford Moses; Charles Blaha; Zohora Iqbal; Clarence Chow; Nathan Wright; William H Fissell; Andrew Zydney; Shuvo Roy
Journal:  PLoS One       Date:  2016-07-20       Impact factor: 3.240

6.  Neutrophil Activation and Neutrophil Extracellular Trap Formation in Dialysis Patients.

Authors:  Scott Bieber; Kimberly A Muczynski; Christian Lood
Journal:  Kidney Med       Date:  2020-09-22

7.  Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis.

Authors:  Adam Locke; Margaret A Bushey; Cynthia LaCroix; Patience Deardoff; Macaulay Amechi Chukwukadibia Onuigbo
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2020-11-06

Review 8.  Influence of Dialysis Membranes on Clinical Outcomes: From History to Innovation.

Authors:  Yee-An Chen; Shuo-Ming Ou; Chih-Ching Lin
Journal:  Membranes (Basel)       Date:  2022-01-26

Review 9.  The role of the ADVanced Organ Support (ADVOS) system in critically ill patients with multiple organ failure.

Authors:  Metesh Acharya; Rafal Berger; Aron-Frederik Popov
Journal:  Artif Organs       Date:  2022-02-06       Impact factor: 2.663

  9 in total