Literature DB >> 30507530

Evaluation of Reconstruction Parameters for 2-D Comb-Push Ultrasound Shear Wave Elastography.

Jorge Racedo, Matthew W Urban.   

Abstract

Shear wave elastography (SWE) is a noninvasive ultrasound imaging modality used in the assessment of the mechanical properties of tissues such as the liver, kidney, skeletal muscle, thyroid, and the breast. Among the methods used to perform SWE is the comb-push ultrasound shear elastography method. This method uses multiple focused ultrasound beams to generate push beams with acoustic radiation force. Applying these push beams generates propagating shear waves. The propagation motion is measured with ultrafast ultrasound imaging. The shear wave motion data are directionally filtered, and a 2-D shear wave velocity (SWV) algorithm is applied to create group velocity maps. This algorithm uses a moving window and a specified patch for performing cross-correlations of time-domain signals. We performed a parametric study of how the choice of the patch and window size affected the reconstruction of the SWV in homogeneous and inclusion phantoms. We quantified the mean velocity and coefficient of variation in the homogeneous phantoms. We measured the contrast-to-noise ratio and bias in the inclusion phantoms. In each of these cases, we found that particular combinations of the patch and window provided optimal values of these evaluation metrics for the phantoms tested. This study provides a basis to construct algorithms to produce optimal SWV reconstructions for various clinical applications.

Entities:  

Mesh:

Year:  2018        PMID: 30507530      PMCID: PMC6375804          DOI: 10.1109/TUFFC.2018.2884348

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  35 in total

1.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping.

Authors:  Jérémy Bercoff; Mickaël Tanter; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-04       Impact factor: 2.725

2.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

3.  A multiresolution approach to shear wave image reconstruction.

Authors:  Peter Hollender; Nick Bottenus; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

4.  Single- and multiple-track-location shear wave and acoustic radiation force impulse imaging: matched comparison of contrast, contrast-to-noise ratio and resolution.

Authors:  Peter J Hollender; Stephen J Rosenzweig; Kathryn R Nightingale; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2015-02-17       Impact factor: 2.998

5.  Multi-source and multi-directional shear wave generation with intersecting steered ultrasound push beams.

Authors:  Alireza Nabavizadeh; Pengfei Song; Shigao Chen; James F Greenleaf; Matthew W Urban
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-04       Impact factor: 2.725

6.  Prediction of Renal Allograft Acute Rejection Using a Novel Non-Invasive Model Based on Acoustic Radiation Force Impulse.

Authors:  Cheng Yang; Yunjie Jin; Shengdi Wu; Long Li; Mushuang Hu; Ming Xu; Ruiming Rong; Tongyu Zhu; Wanyuan He
Journal:  Ultrasound Med Biol       Date:  2016-06-04       Impact factor: 2.998

Review 7.  WFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography: Part 4. Thyroid.

Authors:  David Cosgrove; Richard Barr; Joerg Bojunga; Vito Cantisani; Maria Cristina Chammas; Manjiri Dighe; Sudhir Vinayak; Jun-Mei Xu; Christoph F Dietrich
Journal:  Ultrasound Med Biol       Date:  2016-08-25       Impact factor: 2.998

8.  Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.

Authors:  Ned C Rouze; Michael H Wang; Mark L Palmeri; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-08       Impact factor: 2.725

9.  Shear wave arrival time estimates correlate with local speckle pattern.

Authors:  Stephen A Mcaleavey; Laurentius O Osapoetra; Jonathan Langdon
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-12       Impact factor: 2.725

10.  Liver fibrosis staging with a new 2D-shear wave elastography using comb-push technique: Applicability, reproducibility, and diagnostic performance.

Authors:  Sang Min Lee; Jeong Min Lee; Hyo-Jin Kang; Hyung Kung Yang; Jeong Hee Yoon; Won Chang; Su Joa An; Kyoung Bun Lee; Seung Yon Baek
Journal:  PLoS One       Date:  2017-05-16       Impact factor: 3.240

View more
  2 in total

1.  Three-dimensional shear wave elastography on conventional ultrasound scanners with external vibration.

Authors:  Chengwu Huang; Pengfei Song; Daniel C Mellema; Ping Gong; U-Wai Lok; Shanshan Tang; Wenwu Ling; Duane D Meixner; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  Phys Med Biol       Date:  2020-11-05       Impact factor: 3.609

2.  A Non-invasive Method to Estimate the Stress-Strain Curve of Soft Tissue Using Ultrasound Elastography.

Authors:  Yuqi Wang; Daniel S Jacobson; Matthew W Urban
Journal:  Ultrasound Med Biol       Date:  2022-02-13       Impact factor: 2.998

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.