| Literature DB >> 26654127 |
Lucia Tanga1, Gloria Roberti2, Francesco Oddone3, Luciano Quaranta4, Manuela Ferrazza5, Francesca Berardo6, Gianluca Manni7, Marco Centofanti8,9.
Abstract
BACKGROUND: Spectral-domain optical coherence tomography (SD-OCT) provides fast scan speed and high scan resolution improving its diagnostic accuracy. The purpose of this study was to evaluate if SD-OCT measurements and their quality score are influenced by pupil dilation.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26654127 PMCID: PMC4676126 DOI: 10.1186/s12886-015-0168-y
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Student t-test to compare RNFL overall, GCC average and ONH rim volume measurements pre-and post-dilation between groups
| Glaucoma patients | Healthy subjects | |||||
|---|---|---|---|---|---|---|
| Pre-dilation | Post-dilation |
| Pre-dilation | Post-dilation |
| |
| RNFL overall (μm) | 80 ± 15 | 80 ± 16 | 0.87 | 99 ± 12 | 98 ± 14 | 0.70 |
| GCC average | 81.3 ± 13.4 | 81.1 ± 13.1 | 0.92 | 92.1 ± 6.7 | 91.5 ± 7 | 0.72 |
| ONH rim volume | 0.05 ± 0.11 | 0.04 ± 0.07 | 0.74 | 0.11 ± 0.1 | 0.04 ± 0.07 | 0.36 |
RNFL = retinal nerve fibre layer; GCC = ganglion cell complex; ONH = optic nerve head
Student t test to compare SSI RNFL, SSI GCC and SSI ONH values pre- and post-dilation between groups
| Glaucoma patients | Healthy subjects | |||||
|---|---|---|---|---|---|---|
| Pre-dilation | Post-dilation |
| Pre-dilation | Post-dilation |
| |
| SSI | 54.3 ± 10.3 | 51.7 ± 18.1 | 0.12 | 57 ± 10 | 54 ± 9.3 | 0.2 |
| SSI | 58 ± 9.5 | 57 ± 8 | 0.55 | 60.9 ± 8.1 | 58.8 ± 7.3 | 0.3 |
| ONH rim volume | 48.5 ± 7.6 | 46.6 ± 7.2 | 0.16 | 51.5 ± 8.9 | 50.4 ± 8.3 | 0.59 |
RNFL = retinal nerve fibre layer; GCC = ganglion cell complex; ONH = optic nerve head
Pearson’s correlation coefficient (r) between the variability of pre- and post-dilation of all measurements and the mean quality score of the two measurements
| Glaucoma patients | Healthy subjects | |||
|---|---|---|---|---|
|
|
|
|
| |
| SSI | 0.18 | 0.16 | 0.20 | 0.14 |
| SSI | −0.19 | 0.14 | 0.02 | 0.86 |
| SSI ONH pre dilation-post dilation/mean ONH rim volume | 0.003 | 0.97 | −0.06 | 0.68 |