OBJECTIVE: To evaluate the reliability of nerve fiber layer (NFL) thickness measurements by optical coherence tomography (OCT) in normal and glaucomatous eyes.
DESIGN: Prospective, comparative, observational case series and instrument validation study. PARTICIPANTS: Twenty-four glaucomatous patients were compared with 24 gender- and age-matched normal subjects.
METHODS: Each individual underwent OCT measurements of NFL thickness. Five repetitions of a series of scans on five separate occasions within a 0.5-month period were performed. Each eye was scanned at three different nerve head programs (1.5 radius [R], R = 1.73 mm, 2.0 R). For each option (1.5 R, R = 1.73 mm, and 2.0R) and region (superior, inferior, temporal, nasal, and overall mean), variance components and intraclass correlation coefficients were determined using repeated measures regression. In these models, NFL thickness, as measured by OCT, was assumed to have three variance components: intersubject, intervisit (within-subject between-dates), and intravisit (within-subject within-date). The intraclass correlation coefficient (intersubject variance/total variance) was used as a measure of reliability. MAIN OUTCOME MEASURES: Measurements of NFL thickness using OCT were performed.
RESULTS: Reliability values, as measured by intraclass correlation coefficients, resulted as follows: 1.5 R, 0.54/0.52 (normal/glaucoma); R = 1.73 mm, 0.50/0.50; 2.0 R, 0.49/0.50.
CONCLUSIONS: Our results indicate that the recent commercially available OCT provides reliable NFL thickness measurements in both healthy and glaucomatous eyes with each circle radius tested. The greatest amount of variability can be attributed to intersubject differences.

Entities:  

Mesh:

Year:  2003        PMID: 12511365     DOI: 10.1016/s0161-6420(02)01296-4

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  41 in total

1.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

2.  Optical coherence tomography analysis of axonal loss in band atrophy of the optic nerve.

Authors:  M L R Monteiro; B C Leal; A A M Rosa; M D Bronstein
Journal:  Br J Ophthalmol       Date:  2004-07       Impact factor: 4.638

Review 3.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

4.  Effect of Refractive Status and Axial Length on Peripapillary Retinal Nerve Fibre Layer Thickness: An Analysis Using 3D OCT.

Authors:  V Sowmya; V R Venkataramanan; Vishnu Prasad
Journal:  J Clin Diagn Res       Date:  2015-09-01

5.  Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography.

Authors:  M Smith; A Frost; C M Graham; S Shaw
Journal:  Br J Ophthalmol       Date:  2007-06-07       Impact factor: 4.638

6.  Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.

Authors:  Michelle L Gabriele; Hiroshi Ishikawa; Gadi Wollstein; Richard A Bilonick; Larry Kagemann; Maciej Wojtkowski; Vivek J Srinivasan; James G Fujimoto; Jay S Duker; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

7.  Symmetry between the right and left eyes of the normal retinal nerve fiber layer measured with optical coherence tomography (an AOS thesis).

Authors:  Donald L Budenz
Journal:  Trans Am Ophthalmol Soc       Date:  2008

8.  Retinal nerve fiber structure versus visual field function in patients with ischemic optic neuropathy. A test of a linear model.

Authors:  Donald C Hood; Susan Anderson; Jacinthe Rouleau; Adam S Wenick; Larissa K Grover; Myles M Behrens; Jeffrey G Odel; Andrew G Lee; Randy H Kardon
Journal:  Ophthalmology       Date:  2007-09-17       Impact factor: 12.079

9.  Signal strength is an important determinant of accuracy of nerve fiber layer thickness measurement by optical coherence tomography.

Authors:  Ziqiang Wu; Jingjing Huang; Laurie Dustin; Srinivas R Sadda
Journal:  J Glaucoma       Date:  2009-03       Impact factor: 2.503

10.  Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes.

Authors:  Argyrios Tzamalis; Myron Kynigopoulos; Torsten Schlote; Ivan Haefliger
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-23       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.