Literature DB >> 26644308

Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Mehdi Moini1, Christopher M Rollman2.   

Abstract

We introduce a battery operated capillary electrophoresis electrospray ionization (CE/ESI) source for mass spectrometry with optical isomer separation capability. The source fits in front of low or high resolution mass spectrometers similar to a nanospray source with about the same weight and size. The source has two high voltage power supplies (±25 kV HVPS) capable of operating in forward or reverse polarity modes and powered by a 12 V rechargeable lithium ion battery with operation time of ~10 h. In ultrafast CE mode, in which short narrow capillaries (≤15 μm i.d., 15-25 cm long) and field gradients ≥1000 V/cm are used, peak widths at the base are <1 s wide. Under these conditions, the source provides high resolution separation, including optical isomer resolution in ~1 min. Using a low resolution mass spectrometer (LTQ Velos) with a scan time of 0.07 s/scan, baseline separation of amino acids and their optical isomers were achieved in ~1 min. Moreover, bovine serum albumin (BSA) was analyzed in ~1 min with 56% coverage using the data-dependent MS/MS. Using a high resolution mass spectrometer (Thermo Orbitrap Elite) with 15,000 resolution, the fastest scan time achieved was 0.15 s, which was adequate for CE-MS analysis when optical isomer separation is not required or when the optical isomers were well separated. Figures of merit including a detection limit of 2 fmol and linear dynamic range of two orders of magnitude were achieved for amino acids.

Entities:  

Keywords:  Amino acids; Battery operated CE; Integrated ionization source; Optical isomers; Ultrafast CE

Mesh:

Substances:

Year:  2015        PMID: 26644308     DOI: 10.1007/s13361-015-1314-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  24 in total

1.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

2.  Fast LC-MS/MS method for the determination of amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB and PMA in urine.

Authors:  Marta Concheiro; Susana Maria dos Santos Sadler Simões; Oscar Quintela; Ana de Castro; Mário João Rodrigues Dias; Angelines Cruz; Manuel López-Rivadulla
Journal:  Forensic Sci Int       Date:  2006-11-09       Impact factor: 2.395

3.  Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.

Authors:  Mehdi Moini
Journal:  Anal Chem       Date:  2007-04-21       Impact factor: 6.986

Review 4.  Portable Raman explosives detection.

Authors:  David S Moore; R Jason Scharff
Journal:  Anal Bioanal Chem       Date:  2008-11-21       Impact factor: 4.142

5.  A field deployable gas chromatograph/mass spectrometer for industrial hygiene applications.

Authors:  H V Piltingsrud
Journal:  Am Ind Hyg Assoc J       Date:  1997-08

6.  Development of a miniature mass spectrometer with continuous atmospheric pressure interface.

Authors:  Yanbing Zhai; Yan Feng; Yongzheng Wei; Yuzhuo Wang; Wei Xu
Journal:  Analyst       Date:  2015-04-10       Impact factor: 4.616

7.  Separation of opiate isomers using electrospray ionization and paper spray coupled to high-field asymmetric waveform ion mobility spectrometry.

Authors:  Nicholas E Manicke; Michael Belford
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-24       Impact factor: 3.109

8.  Very fast capillary electrophoresis with electrochemical detection for high-throughput analysis using short, vertically aligned capillaries.

Authors:  Jonas Josef Peter Mark; Paolo Piccinelli; Frank-Michael Matysik
Journal:  Anal Bioanal Chem       Date:  2014-07-11       Impact factor: 4.142

9.  Analysis on the go: quantitation of drugs of abuse in dried urine with digital microfluidics and miniature mass spectrometry.

Authors:  Andrea E Kirby; Nelson M Lafrenière; Brendon Seale; Paul I Hendricks; R Graham Cooks; Aaron R Wheeler
Journal:  Anal Chem       Date:  2014-06-06       Impact factor: 6.986

10.  Pneumatic microvalve-based hydrodynamic sample injection for high-throughput, quantitative zone electrophoresis in capillaries.

Authors:  Ryan T Kelly; Chenchen Wang; Sarah J Rausch; Cheng S Lee; Keqi Tang
Journal:  Anal Chem       Date:  2014-06-09       Impact factor: 6.986

View more