Development of a miniature mass spectrometer with continuous atmospheric pressure interface.

Yanbing Zhai1, Yan Feng, Yongzheng Wei, Yuzhuo Wang, Wei Xu.   

Abstract

The demand for on-the-spot analysis is met by a miniature mass spectrometer which is preferred to be robust, stable, as small as possible and capable of analyzing different samples by coupling with various ionization methods. However, largely constrained by the atmospheric pressure interface (API), these aspects are difficult to be realized in one system. Herein, we describe the development of a new miniature mass spectrometer with balanced performance. The miniature mass spectrometer is small in size (30 × 30 × 18 cm) but has a continuous API, which was achieved by high-pressure ion trap operation and maximized ion transfer efficiency with the utilization of a differential pumping system. The miniature mass spectrometer was characterized and optimized in terms of stability, sensitivity, mass range, mass resolution and scan speed. Rapid analysis of mixtures was demonstrated by coupling the miniature mass spectrometer with the ambient ionization technique of paper spray. This is the smallest miniature mass spectrometer to date, which has a continuous API.

Entities:  

Year:  2015        PMID: 25860539     DOI: 10.1039/c5an00462d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  6 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Authors:  Mehdi Moini; Christopher M Rollman
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-07       Impact factor: 3.109

3.  Reducing Space Charge Effects in a Linear Ion Trap by Rhombic Ion Excitation and Ejection.

Authors:  Xiaohua Zhang; Yuzhuo Wang; Lili Hu; Dan Guo; Xiang Fang; Mingfei Zhou; Wei Xu
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-14       Impact factor: 3.109

4.  Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer.

Authors:  Yuan Tian; Trevor K Decker; Joshua S McClellan; Qinghao Wu; Abraham De la Cruz; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-05       Impact factor: 3.109

Review 5.  Direct sampling mass spectrometry for clinical analysis.

Authors:  Fan Pu; Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Analyst       Date:  2019-02-11       Impact factor: 4.616

Review 6.  Clinical Chemistry for Developing Countries: Mass Spectrometry.

Authors:  Suji Lee; Kavyasree Chintalapudi; Abraham K Badu-Tawiah
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2021-07-27       Impact factor: 10.745

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.