Literature DB >> 26617458

Method of Calibrating Response Statistics for ML Estimation of 3D Interaction Position in a Thick-Detector Gamma Camera.

William C J Hunter1, Harrison H Barrett2, Lars R Furenlid3, Stephen K Moore4.   

Abstract

High-energy photon detectors are often made thick in order to improve their photon-detection efficiency. To avoid issues of parallax and increased signal variance that result from random interaction depth, we must determine the 3D interaction position in the imaging detector. With this goal in mind, we examine a method of calibrating response statistics of a thick-detector gamma camera to produce a maximum- likelihood estimate of 3D interaction position. We parameterize the mean detector response as a function of 3D position and estimate the parameters by maximizing their likelihood given prior knowledge of the pathlength distribution and a complete list of camera signals for an ensemble of gamma-ray interactions. Demonstrating this calibration method with simulated gamma-camera data, we show that the resulting calibration is accurate and can be used to produce unbiased estimates of 3D interaction position.

Year:  2007        PMID: 26617458      PMCID: PMC4659383          DOI: 10.1109/NSSMIC.2007.4437079

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  3 in total

1.  Maximum-likelihood Estimation of 3D Event Position in Monolithic Scintillation Crystals: Experimental Results.

Authors:  S K Moore; W C J Hunter; L R Furenlid; H H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007-10-26

2.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

3.  Maximum likelihood positioning in the scintillation camera using depth of interaction.

Authors:  D Gagnon; N Pouliot; L Laperriere; M Therrien; P Olivier
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

  3 in total
  2 in total

1.  Maximum-likelihood Estimation of 3D Event Position in Monolithic Scintillation Crystals: Experimental Results.

Authors:  S K Moore; W C J Hunter; L R Furenlid; H H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007-10-26

Review 2.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.