Maximum likelihood positioning in the scintillation camera using depth of interaction.

D Gagnon1, N Pouliot, L Laperriere, M Therrien, P Olivier.   

Abstract

Specific effects of the depth of interaction (DOI) on the photomultiplier (PM) response in an Auger gamma camera were quantified. The method was implemented and tested on a Monte Carlo simulator with special care to the noise modeling. Two models were developed, one considering only the geometric aspects of the camera and used for comparison, and one describing a more realistic camera environment. In a typical camera configuration and 140-keV photons, the DOI alone can account for a 6.4-mm discrepancy in position and 12% in energy between two scintillations. Variation of the DOI can still bring additional distortions when photons do not enter the crystal perpendicularly such as in slant hole, cone beam and other focusing collimators. With a 0.95-cm crystal and a 30 degrees slant angle, the obliquity factor can be responsible for a 5.5-mm variation in the event position. Results indicate that both geometrical and stochastic effects of the DOI are definitely reducing the camera performances and should be included in the image formation process.

Year:  1993        PMID: 18218398     DOI: 10.1109/42.222673

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  Method of Calibrating Response Statistics for ML Estimation of 3D Interaction Position in a Thick-Detector Gamma Camera.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid; Stephen K Moore
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

2.  Maximum-likelihood methods in wavefront sensing: stochastic models and likelihood functions.

Authors:  Harrison H Barrett; Christopher Dainty; David Lara
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-02       Impact factor: 2.129

Review 3.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

4.  Detector Light Response Modeling for a Thick Continuous Slab Detector.

Authors:  Robert S Miyaoka; Sung-Kwan Joo; Kisung Lee
Journal:  J Nucl Sci Technol       Date:  2008       Impact factor: 1.599

5.  List-mode likelihood.

Authors:  H H Barrett; T White; L C Parra
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

Review 6.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

7.  Calibration Method for ML Estimation of 3D Interaction Position in a Thick Gamma-Ray Detector.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

8.  Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination.

Authors:  Eric Berg; Emilie Roncali; Will Hutchcroft; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Med Imaging       Date:  2016-06-07       Impact factor: 10.048

9.  Maximum-Likelihood Methods for Processing Signals From Gamma-Ray Detectors.

Authors:  Harrison H Barrett; William C J Hunter; Brian William Miller; Stephen K Moore; Yichun Chen; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

10.  Optimisation of monolithic nanocomposite and transparent ceramic scintillation detectors for positron emission tomography.

Authors:  Keenan J Wilson; Roumani Alabd; Mehran Abolhasan; Mitra Safavi-Naeini; Daniel R Franklin
Journal:  Sci Rep       Date:  2020-01-29       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.