Literature DB >> 26568677

Maximum-likelihood Estimation of 3D Event Position in Monolithic Scintillation Crystals: Experimental Results.

S K Moore1, W C J Hunter1, L R Furenlid1, H H Barrett1.   

Abstract

We present a simple 3D event position-estimation method using raw list-mode acquisition and maximum-likelihood estimation in a modular gamma camera with a thick (25mm) monolithic scintillation crystal. This method involves measuring 2D calibration scans with a well-collimated 511 keV source and fitting each point to a simple depth-dependent light distribution model. Preliminary results show that angled collimated beams appear properly reconstructed.

Keywords:  Depth of interaction (DOI); Emission tomography; PET; SPECT; gamma camera; gamma ray; maximum likelihood; monolithic scintillation crystal

Year:  2007        PMID: 26568677      PMCID: PMC4643317          DOI: 10.1109/NSSMIC.2007.4436923

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  3 in total

1.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

2.  Method of Calibrating Response Statistics for ML Estimation of 3D Interaction Position in a Thick-Detector Gamma Camera.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid; Stephen K Moore
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

3.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

  3 in total
  7 in total

1.  Method of Calibrating Response Statistics for ML Estimation of 3D Interaction Position in a Thick-Detector Gamma Camera.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid; Stephen K Moore
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

2.  Towards continuous-to-continuous 3D imaging in the real world.

Authors:  L Caucci; Z Liu; A K Jha; H Han; L R Furenlid; H H Barrett
Journal:  Phys Med Biol       Date:  2019-09-18       Impact factor: 3.609

3.  Combining Surface Treatments with Shallow Slots to Improve the Spatial Resolution Performance of Continuous, Thick LYSO Detectors for PET.

Authors:  M Kaul; S Surti; J S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-02-01       Impact factor: 1.679

4.  Calibration Method for ML Estimation of 3D Interaction Position in a Thick Gamma-Ray Detector.

Authors:  William C J Hunter; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-10       Impact factor: 1.679

Review 5.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

6.  Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination.

Authors:  Eric Berg; Emilie Roncali; Will Hutchcroft; Jinyi Qi; Simon R Cherry
Journal:  IEEE Trans Med Imaging       Date:  2016-06-07       Impact factor: 10.048

7.  Maximum-Likelihood Methods for Processing Signals From Gamma-Ray Detectors.

Authors:  Harrison H Barrett; William C J Hunter; Brian William Miller; Stephen K Moore; Yichun Chen; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

  7 in total