Literature DB >> 26584144

Development and evaluation of a multichannel endorectal RF coil for prostate MRI at 7T in combination with an external surface array.

M Arcan Ertürk1, Jinfeng Tian1, Pierre-François Van de Moortele1, Gregor Adriany1, Gregory J Metzger1.   

Abstract

PURPOSE: To develop and evaluate a sterilizable multichannel endorectal coil (ERC) for use in combination with an external surface array (ESA) for high-resolution anatomical and functional studies of the prostate at 7T.
MATERIALS AND METHODS: A two-loop ERC (ERC-2L) and a microstrip-loop ERC (ERC-ML) were compared at 7T in terms of transmit and receive performance. The best-performing ERC was evaluated alone and in combination with the ESA through 1) simulations on both phantom and an anatomically correct numerical human model to assess B1+ transmit and specific absorption rate (SAR) efficiencies, and 2) phantom experiments to calculate B1+ transmit efficiency and signal-to-noise ratio (SNR). Phantom studies were also performed to look at heating when using the ERC as a transmitter and for comparing the new coil against a single-channel balloon-type ERC (ERC-b). High-resolution magnetic resonance imaging (MRI) acquisitions were performed on a single healthy subject using the two-channel ERC combined with the ESA.
RESULTS: Compared to the ERC-ML, the ERC-2L demonstrated 20% higher SAR efficiency and higher SNR 3 cm from the coil. The presence of a tuned and detuned ERC-2L did not alter the peak local SAR of the ESA alone; however, the detuned ERC-2L had 45% less peak local SAR around the rectum compared to the tuned ERC-2L. The receive-only version of the ERC-2L improved the SNR 4.7-fold and 1.3-fold compared to the ESA and ERC-b, respectively. In combination with the ESA, the ERC-2L supported in-plane voxel-size of 0.36 × 0.36 mm(2) in T2 -weighted anatomic imaging.
CONCLUSION: The reusable ERC-2L combined with an ESA offers a high SNR imaging platform for translational studies of the prostate at 7T. J. Magn. Reson. Imaging 2016;43:1279-1287.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  7 Tesla body imaging; MRI; endorectal coil; prostate; prostate cancer; ultrahigh field

Mesh:

Year:  2015        PMID: 26584144      PMCID: PMC4865450          DOI: 10.1002/jmri.25099

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  34 in total

1.  Improving SNR and B1 transmit field for an endorectal coil in 7 T MRI and MRS of prostate cancer.

Authors:  C S Arteaga de Castro; B van den Bergen; P R Luijten; U A van der Heide; M van Vulpen; D W J Klomp
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

2.  Development of multiorgan finite element-based prostate deformation model enabling registration of endorectal coil magnetic resonance imaging for radiotherapy planning.

Authors:  Jennifer M Hensel; Cynthia Ménard; Peter W M Chung; Michael F Milosevic; Anna Kirilova; Joanne L Moseley; Masoom A Haider; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-08-01       Impact factor: 7.038

Review 3.  Prostate MR imaging at high-field strength: evolution or revolution?

Authors:  Olivier Rouvière; Robert P Hartman; Denis Lyonnet
Journal:  Eur Radiol       Date:  2005-09-10       Impact factor: 5.315

4.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements.

Authors:  Gregory J Metzger; Carl Snyder; Can Akgun; Tommy Vaughan; Kamil Ugurbil; Pierre-Francois Van de Moortele
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

5.  A clinical comparison of rigid and inflatable endorectal-coil probes for MRI and 3D MR spectroscopic imaging (MRSI) of the prostate.

Authors:  Susan M Noworolski; Jason C Crane; Daniel B Vigneron; John Kurhanewicz
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

6.  Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performance.

Authors:  Stijn W T P J Heijmink; Jurgen J Fütterer; Thomas Hambrock; Satoru Takahashi; Tom W J Scheenen; Henkjan J Huisman; Christina A Hulsbergen-Van de Kaa; Ben C Knipscheer; Lambertus A L M Kiemeney; J Alfred Witjes; Jelle O Barentsz
Journal:  Radiology       Date:  2007-05-10       Impact factor: 11.105

7.  Initial results of cardiac imaging at 7 Tesla.

Authors:  C J Snyder; L DelaBarre; G J Metzger; P-F van de Moortele; C Akgun; K Ugurbil; J T Vaughan
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

8.  Whole-body imaging at 7T: preliminary results.

Authors:  J Thomas Vaughan; Carl J Snyder; Lance J DelaBarre; Patrick J Bolan; Jinfeng Tian; Lizann Bolinger; Gregor Adriany; Peter Andersen; John Strupp; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

9.  Dynamic contrast-enhanced MRI of prostate cancer at 3 T: a study of pharmacokinetic parameters.

Authors:  Iclal Ocak; Marcelino Bernardo; Greg Metzger; Tristan Barrett; Peter Pinto; Paul S Albert; Peter L Choyke
Journal:  AJR Am J Roentgenol       Date:  2007-10       Impact factor: 3.959

10.  Expandable and rigid endorectal coils for prostate MRI: impact on prostate distortion and rigid image registration.

Authors:  Yongbok Kim; I-Chow J Hsu; Jean Pouliot; Susan Moyher Noworolski; Daniel B Vigneron; John Kurhanewicz
Journal:  Med Phys       Date:  2005-12       Impact factor: 4.071

View more
  11 in total

1.  Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra-high field MRI.

Authors:  Alireza Sadeghi-Tarakameh; Gregor Adriany; Gregory J Metzger; Russell L Lagore; Steve Jungst; Lance DelaBarre; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2020-06-23       Impact factor: 4.668

2.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

3.  Toward imaging the body at 10.5 tesla.

Authors:  M Arcan Ertürk; Xiaoping Wu; Yiğitcan Eryaman; Pierre-François Van de Moortele; Edward J Auerbach; Russell L Lagore; Lance DelaBarre; J Thomas Vaughan; Kâmil Uğurbil; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-10-21       Impact factor: 4.668

4.  A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna.

Authors:  Alireza Sadeghi-Tarakameh; Steve Jungst; Mike Lanagan; Lance DelaBarre; Xiaoping Wu; Gregor Adriany; Gregory J Metzger; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2021-11-26       Impact factor: 4.668

Review 5.  Ultra-high-field MR in Prostate cancer: Feasibility and Potential.

Authors:  Carlijn J A Tenbergen; Gregory J Metzger; Tom W J Scheenen
Journal:  MAGMA       Date:  2022-05-17       Impact factor: 2.533

6.  A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI.

Authors:  M Arcan Ertürk; Alexander J E Raaijmakers; Gregor Adriany; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-02-17       Impact factor: 4.668

7.  Design of a forward view antenna for prostate imaging at 7 T.

Authors:  Bart R Steensma; Ingmar Voogt; Abe J van der Werf; Cornelis A T van den Berg; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers
Journal:  NMR Biomed       Date:  2018-07-18       Impact factor: 4.044

Review 8.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06

9.  Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

Authors:  Bart Steensma; Pierre-Francois van de Moortele; Arcan Ertürk; Andrea Grant; Gregor Adriany; Peter Luijten; Dennis Klomp; Nico van den Berg; Gregory Metzger; Alexander Raaijmakers
Journal:  Magn Reson Med       Date:  2020-05-05       Impact factor: 4.668

10.  Prostate MRI using a rigid two-channel phased-array endorectal coil: comparison with phased array coil acquisition at 3 T.

Authors:  Sara Lewis; Aasrith Ganti; Pamela Argiriadi; Ally Rosen; Stefanie Hectors; Sahar Semaan; Christopher Song; Steve Peti; Maxwell Segall; Kezia George; Vaneela Jaikaran; Sebastian Villa; David Kestenbaum; Nicholas Voutsinas; John Doucette; Ashutosh Tewari; Ardeshir R Rastinehad; Bachir Taouli
Journal:  Cancer Imaging       Date:  2022-03-16       Impact factor: 3.909

View more