Literature DB >> 23036786

The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT.

Yang Hou1, Shu Xu, Wenli Guo, Mani Vembar, Qiyong Guo.   

Abstract

AIM: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose(4)) from prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (coronary CTA) on a 256-slice multi-detector CT (MDCT) scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). METHOD AND MATERIALS: 110 consecutive patients (69 men, 41 women; age: 54 ± 10 years) underwent coronary CTA on a 256-slice MDCT (Brilliance iCT, Philips Healthcare). The control group (Group A, n=21) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 4 groups were scanned with the same kVp but successively reduced tube output as follows: B[n=15]: 125 mAs; C[n=22]: 105 mAs; D[n=36]: 84 mAs: E[n=16]: 65 mAs) and reconstructed using IR levels of L3 (Group B), L4 (Group C) and L5 (Groups D and E), to compensate for the noise increase. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4 - excellent, 3 - good, 2 - fair and 1 - poor). Quantitative measurements of CT values, image noise and contrast-to-noise (CNR) were measured in each group. A receiver-operating characteristic (ROC) analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained.
RESULTS: There were no significant differences in objective noise, SNR and CNR values among Groups A, B, C, D, and E (P=0.14, 0.09, 0.17, respectively). There were no significant differences in the scores of the subjective IQ between Group A, and Groups B, C, D, E (P=0.23-0.97). Significant differences in image sharpness and study acceptability were observed between groups A and E (P<0.05). Using the criterion of excellent IQ (score 4), the ROC curve of dose levels and IQ acceptability established a reduction of 60% of tube output (Group D) as optimum cutoff point (AUC: 0.72, 95% CI: 0.59-0.86). Group D (84 mAs with L5) provided equivalent subjective image ranking (with lumen sharpness taken into account) and objective IQ measurements (noise: 36.5 ± 10.7; SNR: 13.6 ± 4.9; CNR: 16.28 ± 5.4) compared with FBP images in Group A (noise: 35.5 ± 9.4; SNR: 12.4 ± 2.5; CNR: 15.4 ± 3.2) (P=0.14, 0.09, 0.17, respectively). The effective dose (ED) of Group D was 63% lower than that of Group A (1.2 ± 0.1 mSv versus 3.2 ± 0.6 mSv).
CONCLUSION: Iterative reconstruction techniques can provide 63% ED reduction in prospectively-triggered coronary CTA using 256-slice MDCT while maintaining excellent image quality.
Copyright © 2012. Published by Elsevier Ireland Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 23036786     DOI: 10.1016/j.ejrad.2012.06.022

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  20 in total

Review 1.  Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis.

Authors:  Annemarie M Den Harder; Martin J Willemink; Quirina M B De Ruiter; Pim A De Jong; Arnold M R Schilham; Gabriel P Krestin; Tim Leiner; Ricardo P J Budde
Journal:  Br J Radiol       Date:  2015-11-12       Impact factor: 3.039

2.  The effect of iterative reconstruction on quantitative computed tomography assessment of coronary plaque composition.

Authors:  Richard A P Takx; Martin J Willemink; Hendrik M Nathoe; Arnold M R Schilham; Ricardo P J Budde; Pim A de Jong; Tim Leiner
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-18       Impact factor: 2.357

3.  Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties.

Authors:  Martijn F Boomsma; Mireille A Edens; Christiaan P Van Lingen; Niek Warringa; Harmen B Ettema; Cees C P M Verheyen; Mario Maas
Journal:  Skeletal Radiol       Date:  2015-05-06       Impact factor: 2.199

4.  Neointimal formation after carotid artery stenting: phantom and clinical evaluation of model-based iterative reconstruction (MBIR).

Authors:  Kazushi Yokomachi; Fuminari Tatsugami; Toru Higaki; Shinji Kume; Shigeyuki Sakamoto; Takahito Okazaki; Kaoru Kurisu; Yuko Nakamura; Yasutaka Baba; Makoto Iida; Kazuo Awai
Journal:  Eur Radiol       Date:  2018-06-22       Impact factor: 5.315

5.  [Registration and monitoring of radiation exposure from radiological imaging].

Authors:  F Jungmann; D Pinto dos Santos; J Hempel; C Düber; P Mildenberger
Journal:  Radiologe       Date:  2013-06       Impact factor: 0.635

6.  Diagnostic accuracy of in-stent restenosis using model-based iterative reconstruction at coronary CT angiography: initial experience.

Authors:  Fuminari Tatsugami; Toru Higaki; Hiroaki Sakane; Yuko Nakamura; Makoto Iida; Yasutaka Baba; Chikako Fujioka; Atsuhiro Senoo; Toshiro Kitagawa; Hideya Yamamoto; Yasuki Kihara; Kazuo Awai
Journal:  Br J Radiol       Date:  2017-10-27       Impact factor: 3.039

7.  Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality.

Authors:  Davide Ippolito; Davide Fior; Cammillo Talei Franzesi; Luca Riva; Alessandra Casiraghi; Sandro Sironi
Journal:  Radiol Med       Date:  2017-08-28       Impact factor: 3.469

8.  Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease.

Authors:  Yang Hou; Yue Ma; Weipeng Fan; Yuke Wang; Mei Yu; Mani Vembar; Qiyong Guo
Journal:  Eur Radiol       Date:  2013-07-26       Impact factor: 5.315

Review 9.  Cardiac PET-CT for monitoring medical and interventional therapy in patients with CAD: PET alone versus hybrid PET-CT?

Authors:  Quynh A Truong; Henry Gewirtz
Journal:  Curr Cardiol Rep       Date:  2014-03       Impact factor: 2.931

10.  Sex differences in the effectiveness of early coronary computed tomographic angiography compared with standard emergency department evaluation for acute chest pain: the rule-out myocardial infarction with Computer-Assisted Tomography (ROMICAT)-II Trial.

Authors:  Quynh A Truong; Douglas Hayden; Pamela K Woodard; Ruth Kirby; Eric T Chou; John T Nagurney; Stephen D Wiviott; Jerome L Fleg; David A Schoenfeld; James E Udelson; Udo Hoffmann
Journal:  Circulation       Date:  2013-05-17       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.