Literature DB >> 26529610

Electrophysiological Detection of Scalar-Changing Perimodiolar Cochlear Electrode Arrays: A Six-Month Follow-Up Study.

Philipp Mittmann1, Ingo Todt, Thomas Wesarg, Susan Arndt, Arneborg Ernst, Frederike Hassepass.   

Abstract

The position of the cochlear electrode array within the scala tympani is essential for optimal hearing benefit. An intraoperative neural response telemetry ratio (NRT ratio; a threshold ratio of pairs of apical and basal electrodes) has been established, which can provide information about the intracochlear electrode array position. Out of a previous collective of 85 patients, the 6-month follow-up electrophysiological NRT data of 37 patients have been included in this study. Comparing the intraoperatively estimated NRT ratio with the 6-month follow-up NRT ratio, it remained unchanged intraindividually in 92% of cases. Within this group the NRT ratio and the intracochlear position of the electrode array matched in all cases. There were two newly occurring mismatches and one new match was observed. After a period of 6 months the NRT ratio remained unchanged in most cases and showed a good correlation with the intracochlear position of the electrode array.
© 2015 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2015        PMID: 26529610     DOI: 10.1159/000441346

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  4 in total

1.  Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study.

Authors:  Philipp Mittmann; I Todt; A Ernst; G Rademacher; S Mutze; S Göricke; M Schlamann; R Ramalingam; S Lang; F Christov; D Arweiler-Harbeck
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-06-28       Impact factor: 2.503

2.  Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series.

Authors:  P Mittmann; G Lauer; A Ernst; S Mutze; F Hassepass; S Arndt; D Arweiler-Harbeck; F Christov
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-09-24       Impact factor: 2.503

Review 3.  Review on cochlear implant electrode array tip fold-over and scalar deviation.

Authors:  Anandhan Dhanasingh; Claude Jolly
Journal:  J Otol       Date:  2019-01-09

4.  Simpler and effective radiological evaluations for modiolar proximity of a slim modiolar cochlear implant electrode.

Authors:  Sang-Yeon Lee; Jin Hee Han; Marge Carandang; Yun Jung Bae; Byung Yoon Choi
Journal:  Sci Rep       Date:  2020-10-19       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.