Literature DB >> 12216591

A field comparison of the IOM inhalable aerosol sampler and a modified 37-mm cassette.

R E Clinkenbeard1, E C England, D L Johnson, N A Esmen, T A Hall.   

Abstract

This research focused on comparing a modified 37-mm (Mod37) sampling cassette with an IOM inhalable dust sampler. Paired IOM and Mod37 breathing-zone air samples were collected for workers engaged in corrosion control maintenance operations on several types of aircraft at several U.S. Air Force bases in the United States. Sampled operations included hand and power sanding, blow-down and wipe-down to remove dust, and spray finishing. The cassettes' interior surfaces were swabbed and the swabs combined with the filters for chromium analysis by NIOSH Method 7300. This approach utilized total chromium as a sensitive surrogate indicator of total aspirated mass. The influences of work location, work type, sample duration, and sampler type on measured concentration were evaluated using analysis of variance techniques. Only work type (process) was found to be a statistically significant predictor of measured concentration. The relationship between IOM- and Mod37-measured values for paired samples was evaluated by work type using linear regression techniques. Linear regressions showed that the modified 37-mm cassette over-samples aerosol by 35 percent compared to the IOM when a wide range of aerosol concentrations and compositions for divergent work tasks in multiple field locations are sampled. Interpretation of these results in light of previous results involving filter-only Mod37 analyses suggests that while the Mod37 has a higher aspiration efficiency than the IOM, substantial Mod37 wall losses result in underestimation of exposure when only the 37-mm filter is analyzed rather than filters plus wall swabs.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12216591     DOI: 10.1080/10473220290095943

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  3 in total

1.  Solid versus liquid particle sampling efficiency of three personal aerosol samplers when facing the wind.

Authors:  Kirsten A Koehler; T Renee Anthony; Michael Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2011-09-29

2.  Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

Authors:  T Renée Anthony; Darrah Sleeth; John Volckens
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

Review 3.  Operationalizing the Exposome Using Passive Silicone Samplers.

Authors:  Zoe Coates Fuentes; Yuri Levin Schwartz; Anna R Robuck; Douglas I Walker
Journal:  Curr Pollut Rep       Date:  2022-01-04
  3 in total