Literature DB >> 26512231

Design of an Optically Controlled MR-Compatible Active Needle.

Seok Chang Ryu1, Zhan Fan Quek1, Je-Sung Koh2, Pierre Renaud3, Richard J Black4, Behzad Moslehi4, Bruce L Daniel5, Kyu-Jin Cho6, Mark R Cutkosky1.   

Abstract

An active needle is proposed for the development of magnetic resonance imaging (MRI)-guided percutaneous procedures. The needle uses a low-transition-temperature shape memory alloy (LT SMA) wire actuator to produce bending in the distal section of the needle. Actuation is achieved with internal optical heating using laser light transported via optical fibers and side coupled to the LT SMA. A prototype, with a size equivalent to a standard 16-gauge biopsy needle, exhibits significant bending, with a tip deflection of more than 14° in air and 5° in hard tissue. A single-ended optical sensor with a gold-coated tip is developed to measure the curvature independently of temperature. The experimental results in tissue phantoms show that human tissue causes fast heat dissipation from the wire actuator; however, the active needle can compensate for typical targeting errors during prostate biopsy.

Entities:  

Keywords:  Active needle; mechanism design; medical robots and systems; optical actuation and sensing

Year:  2015        PMID: 26512231      PMCID: PMC4620588          DOI: 10.1109/TRO.2014.2367351

Source DB:  PubMed          Journal:  IEEE Trans Robot        ISSN: 1552-3098            Impact factor:   5.567


  22 in total

1.  MRI-guided prostate brachytherapy with single needle method--a planning study.

Authors:  Marion P R Van Gellekom; Marinus A Moerland; Jan J Battermann; Jan J W Lagendijk
Journal:  Radiother Oncol       Date:  2004-06       Impact factor: 6.280

2.  Needle steering and motion planning in soft tissues.

Authors:  Simon P DiMaio; S E Salcudean
Journal:  IEEE Trans Biomed Eng       Date:  2005-06       Impact factor: 4.538

3.  Flexible needle steering for percutaneous therapies.

Authors:  Daniel Glozman; Moshe Shoham
Journal:  Comput Aided Surg       Date:  2006-07

4.  Robotic palpation-based mechanical property mapping for diagnosis of prostate cancer.

Authors:  Bummo Ahn; Enrique Ian S Lorenzo; Koon Ho Rha; Hyung Joo Kim; Jung Kim
Journal:  J Endourol       Date:  2011-04-14       Impact factor: 2.942

5.  Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

Authors:  Philip Blumenfeld; Nobuhiko Hata; Simon DiMaio; Kelly Zou; Steven Haker; Gabor Fichtinger; Clare M C Tempany
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

6.  Effects of different insertion methods on reducing needle deflection.

Authors:  Niki Abolhassani; Rajni Patel; Farzam Ayazi
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

7.  Robotic image-guided needle interventions of the prostate.

Authors:  Pierre C Mozer; Alan W Partin; Dan Stoianovici
Journal:  Rev Urol       Date:  2009

8.  Correlation of thermal properties of some human tissue with water content.

Authors:  T E Cooper; G J Trezek
Journal:  Aerosp Med       Date:  1971-01

9.  Mechanics of Flexible Needles Robotically Steered through Soft Tissue.

Authors:  S Misra; K B Reed; B W Schafer; K T Ramesh; A M Okamura
Journal:  Int J Rob Res       Date:  2010-11       Impact factor: 4.703

10.  Overcoming pubic arch interference with free-hand needle placement in men undergoing prostate brachytherapy.

Authors:  Erin P Gibbons; Ryan P Smith; Sushil Beriwal; Komanduri Krishna; Ronald M Benoit
Journal:  Brachytherapy       Date:  2008-09-14       Impact factor: 2.362

View more
  7 in total

1.  Highly Articulated Robotic Needle Achieves Distributed Ablation of Liver Tissue.

Authors:  Giada Gerboni; Joseph D Greer; Paul F Laeseke; Gloria L Hwang; Allison M Okamura
Journal:  IEEE Robot Autom Lett       Date:  2017-02-14

2.  Simulation and experimental studies in needle-tissue interactions.

Authors:  Bardia Konh; Mohammad Honarvar; Kurosh Darvish; Parsaoran Hutapea
Journal:  J Clin Monit Comput       Date:  2016-07-18       Impact factor: 2.502

3.  State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.

Authors:  Hao Su; Ka-Wai Kwok; Kevin Cleary; Iulian Iordachita; M Cenk Cavusoglu; Jaydev P Desai; Gregory S Fischer
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-05-03       Impact factor: 14.910

4.  Modular robotic platform for precision neurosurgery with a bio-inspired needle: System overview and first in-vivo deployment.

Authors:  Riccardo Secoli; Eloise Matheson; Marlene Pinzi; Stefano Galvan; Abdulhamit Donder; Thomas Watts; Marco Riva; Davide Danilo Zani; Lorenzo Bello; Ferdinando Rodriguez Y Baena
Journal:  PLoS One       Date:  2022-10-19       Impact factor: 3.752

5.  Methods for Improving the Curvature of Steerable Needles in Biological Tissue.

Authors:  Troy K Adebar; Joseph D Greer; Paul F Laeseke; Gloria L Hwang; Allison M Okamura
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-01       Impact factor: 4.538

6.  Design of an ultra-thin steerable probe for percutaneous interventions and preliminary evaluation in a gelatine phantom.

Authors:  Marta Scali; Paulien A H Veldhoven; Paul W J Henselmans; Dimitra Dodou; Paul Breedveld
Journal:  PLoS One       Date:  2019-09-04       Impact factor: 3.240

7.  Axially rigid steerable needle with compliant active tip control.

Authors:  M de Vries; J Sikorski; S Misra; J J van den Dobbelsteen
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.