Literature DB >> 17729363

Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

Philip Blumenfeld1, Nobuhiko Hata, Simon DiMaio, Kelly Zou, Steven Haker, Gabor Fichtinger, Clare M C Tempany.   

Abstract

PURPOSE: To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate.
MATERIALS AND METHODS: A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated.
RESULTS: The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm.
CONCLUSION: Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17729363     DOI: 10.1002/jmri.21067

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  32 in total

1.  Accuracy study of a robotic system for MRI-guided prostate needle placement.

Authors:  Reza Seifabadi; Nathan B J Cho; Sang-Eun Song; Junichi Tokuda; Nobuhiko Hata; Clare M Tempany; Gabor Fichtinger; Iulian Iordachita
Journal:  Int J Med Robot       Date:  2012-06-08       Impact factor: 2.547

2.  Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images.

Authors:  Gustaaf J Vrooijink; Momen Abayazid; Sachin Patil; Ron Alterovitz; Sarthak Misra
Journal:  Int J Rob Res       Date:  2014-09       Impact factor: 4.703

3.  PROBABILISTIC NON-RIGID REGISTRATION OF PROSTATE IMAGES: MODELING AND QUANTIFYING UNCERTAINTY.

Authors:  Petter Risholm; Andriy Fedorov; Jennifer Pursley; Kemal Tuncali; Robert Cormack; William M Wells
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2011-06-09

4.  Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions.

Authors:  Yong-Lae Park; Santhi Elayaperumal; Bruce Daniel; Seok Chang Ryu; Mihye Shin; Joan Savall; Richard J Black; Behzad Moslehi; Mark R Cutkosky
Journal:  IEEE ASME Trans Mechatron       Date:  2010-12       Impact factor: 5.303

5.  Software strategy for robotic transperineal prostate therapy in closed-bore MRI.

Authors:  Junichi Tokuda; Gregory S Fischer; Csaba Csoma; Simon P DiMaio; David G Gobbi; Gabor Fichtinger; Clare M Tempany; Nobuhiko Hata
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

6.  Open MR-guided high-dose-rate (HDR) prostate brachytherapy: feasibility and initial experiences open MR-guided high-dose-rate (HDR) prostate brachytherapy.

Authors:  Ferenc Lakosi; Gergely Antal; Csaba Vandulek; Arpad Kovacs; Gabor L Toller; Istvan Rakasz; Gabor Bajzik; Janaki Hadjiev; Peter Bogner; Imre Repa
Journal:  Pathol Oncol Res       Date:  2011-01-11       Impact factor: 3.201

7.  Deflection Analysis of Different Needle Designs for Prostate Biopsy and Focal Therapy.

Authors:  Nelson N Stone; Vladimir Mouraviev; David Schechter; Josh Goetz; M Scott Lucia; E Erin Smith; E David Crawford
Journal:  Technol Cancer Res Treat       Date:  2016-10-05

8.  A Study of Needle Image Artifact Localization in Confirmation Imaging of MRI-guided Robotic Prostate Biopsy.

Authors:  Sang-Eun Song; Nathan B Cho; Iulian I Iordachita; Peter Guion; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Int Conf Robot Autom       Date:  2011-08-15

9.  MR Safe Robot, FDA Clearance, Safety and Feasibility Prostate Biopsy Clinical Trial.

Authors:  Dan Stoianovici; Chunwoo Kim; Doru Petrisor; Changhan Jun; Sunghwan Lim; Mark W Ball; Ashley Ross; Katarzyna J Macura; Mohamad Allaf
Journal:  IEEE ASME Trans Mechatron       Date:  2016-10-20       Impact factor: 5.303

10.  Transperineal prostate biopsy: analysis of a uniform core sampling pattern that yields data on tumor volume limits in negative biopsies.

Authors:  Gordon R Kepner; Jeremy V Kepner
Journal:  Theor Biol Med Model       Date:  2010-06-17       Impact factor: 2.432

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.