Literature DB >> 21170164

Mechanics of Flexible Needles Robotically Steered through Soft Tissue.

S Misra1, K B Reed, B W Schafer, K T Ramesh, A M Okamura.   

Abstract

The tip asymmetry of a bevel-tip needle results in the needle naturally bending when it is inserted into soft tissue. This enables robotic needle steering, which can be used in medical procedures to reach subsurface targets inaccessible by straight-line trajectories. However, accurate path planning and control of needle steering requires models of needle-tissue interaction. Previous kinematic models required empirical observations of each needle and tissue combination in order to fit model parameters. This study describes a mechanics-based model of robotic needle steering, which can be used to predict needle behavior and optimize system design based on fundamental mechanical and geometrical properties of the needle and tissue. We first present an analytical model for the loads developed at the tip, based on the geometry of the bevel edge and material properties of soft-tissue simulants (gels). We then present a mechanics-based model that calculates the deflection of a bevel-tipped needle inserted through a soft elastic medium. The model design is guided by microscopic observations of needle-gel interactions. The energy-based formulation incorporates tissue-specific parameters, and the geometry and material properties of the needle. Simulation results follow similar trends (deflection and radius of curvature) to those observed in experimental studies of robotic needle insertion.

Entities:  

Year:  2010        PMID: 21170164      PMCID: PMC3002232          DOI: 10.1177/0278364910369714

Source DB:  PubMed          Journal:  Int J Rob Res        ISSN: 0278-3649            Impact factor:   4.703


  13 in total

1.  Force modeling for needle insertion into soft tissue.

Authors:  Allison M Okamura; Christina Simone; Mark D O'Leary
Journal:  IEEE Trans Biomed Eng       Date:  2004-10       Impact factor: 4.538

2.  Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin.

Authors:  Oliver A Shergold; Norman A Fleck
Journal:  J Biomech Eng       Date:  2005-10       Impact factor: 2.097

3.  Interactive simulation of needle insertion models.

Authors:  Simon P DiMaio; Septimiu E Salcudean
Journal:  IEEE Trans Biomed Eng       Date:  2005-07       Impact factor: 4.538

Review 4.  Needle insertion into soft tissue: a survey.

Authors:  Niki Abolhassani; Rajni Patel; Mehrdad Moallem
Journal:  Med Eng Phys       Date:  2006-08-28       Impact factor: 2.242

5.  Deflection of a flexible needle during insertion into soft tissue.

Authors:  Niki Abolhassani; Rajni V Patel
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

6.  Flexible needle-tissue interaction modeling with depth-varying mean parameter: preliminary study.

Authors:  Kai Guo Yan; Tarun Podder; Yan Yu; Tien-I Liu; Christopher W S Cheng; Wan Sing Ng
Journal:  IEEE Trans Biomed Eng       Date:  2009-02       Impact factor: 4.538

7.  Image Guidance of Flexible Tip-Steerable Needles.

Authors:  Vinutha Kallem; Noah J Cowan
Journal:  IEEE Trans Robot       Date:  2009-02-03       Impact factor: 5.567

8.  Estimation of Model Parameters for Steerable Needles.

Authors:  Wooram Park; Kyle B Reed; Allison M Okamura; Gregory S Chirikjian
Journal:  IEEE Int Conf Robot Autom       Date:  2010

9.  Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review.

Authors:  Sarthak Misra; K T Ramesh; Allison M Okamura
Journal:  Presence (Camb)       Date:  2008-10-01

10.  Needle-Tissue Interaction Forces for Bevel-Tip Steerable Needles.

Authors:  Sarthak Misra; Kyle B Reed; Andrew S Douglas; K T Ramesh; Allison M Okamura
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2008-10-19
View more
  41 in total

1.  Estimating needle tip deflection in biological tissue from a single transverse ultrasound image: application to brachytherapy.

Authors:  Carlos Rossa; Ron Sloboda; Nawaid Usmani; Mahdi Tavakoli
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-11-28       Impact factor: 2.924

2.  Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images.

Authors:  Gustaaf J Vrooijink; Momen Abayazid; Sachin Patil; Ron Alterovitz; Sarthak Misra
Journal:  Int J Rob Res       Date:  2014-09       Impact factor: 4.703

3.  An Autoclavable Steerable Cannula Manual Deployment Device: Design and Accuracy Analysis.

Authors:  Jessica Burgner; Philip J Swaney; Trevor L Bruns; Marlena S Clark; D Caleb Rucker; E Clif Burdette; Robert J Webster
Journal:  J Med Device       Date:  2012-11-21       Impact factor: 0.582

4.  Experimental evaluation of ultrasound-guided 3D needle steering in biological tissue.

Authors:  Momen Abayazid; Gustaaf J Vrooijink; Sachin Patil; Ron Alterovitz; Sarthak Misra
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-22       Impact factor: 2.924

5.  Sliding Mode Control of Steerable Needles.

Authors:  D Caleb Rucker; Jadav Das; Hunter B Gilbert; Philip J Swaney; Michael I Miga; Nilanjan Sarkar; Robert J Webster
Journal:  IEEE Trans Robot       Date:  2013-10       Impact factor: 5.567

6.  A novel approach to an automated needle insertion in brachytherapy procedures.

Authors:  Ivan M Buzurovic; Slavisa Salinic; Peter F Orio; Paul L Nguyen; Robert A Cormack
Journal:  Med Biol Eng Comput       Date:  2017-07-15       Impact factor: 2.602

7.  Highly Articulated Robotic Needle Achieves Distributed Ablation of Liver Tissue.

Authors:  Giada Gerboni; Joseph D Greer; Paul F Laeseke; Gloria L Hwang; Allison M Okamura
Journal:  IEEE Robot Autom Lett       Date:  2017-02-14

8.  A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

Authors:  Iris De Falco; Costanza Culmone; Arianna Menciassi; Jenny Dankelman; John J van den Dobbelsteen
Journal:  Med Biol Eng Comput       Date:  2018-06-04       Impact factor: 2.602

9.  Needle insertion with duty-cycled rotation into multiple media.

Authors:  Craig A Lehocky; Cameron N Riviere
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

10.  Preoperative Needle Insertion Path Planning for Minimizing Deflection in Multilayered Tissues.

Authors:  Ryosuke Tsumura; Jin Seob Kim; Hiroyasu Iwata; Iulian Iordachita
Journal:  IEEE Robot Autom Lett       Date:  2018-02-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.