Literature DB >> 26507523

Impact of the Femoral Head Position on Moment Arms in Total Hip Arthroplasty: A Parametric Finite Element Study.

Hannes A Rüdiger1, Valérie Parvex2, Alexandre Terrier3.   

Abstract

BACKGROUND: Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of this study was to calculate moment arms after nonanatomical femoral reconstruction.
METHODS: Finite element models of 15 patients including the pelvis, the femur, and the gluteal muscles were developed. Moment arms were calculated within the native anatomy and compared to distinct displacement of the femoral center of rotation (leg lengthening of 10 mm, loss of femoral offset of 20%, anteversion ±10°, and fixed anteversion at 15°). Calculations were performed within the range of motion observed during a normal gait cycle.
RESULTS: Although with all evaluated displacements of the femoral center of rotation, the abductor moment arm remained positive, some fibers initially contributing to extension became antagonists (flexors) and vice versa. A loss of 20% of femoral offset led to an average decrease of 15% of abductor moment. Femoral lengthening and changes in femoral anteversion (±10°, fixed at 15°) led to minimal changes in abductor moment arms (maximum change of 5%). Native femoral anteversion correlated with the changes in moment arms induced by the 5 variations of reconstruction.
CONCLUSION: Accurate reconstruction of offset is important to maintaining abductor moment arms, while changes of femoral rotation had minimal effects. Patients with larger native femoral anteversion appear to be more susceptible to femoral head displacements.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  arthroplasty; biomechanics; center of rotation; hip; moment arm; muscle

Mesh:

Year:  2015        PMID: 26507523     DOI: 10.1016/j.arth.2015.09.044

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.

Authors:  Julien Wegrzyn; Jean-Paul Roux; Charlotte Loriau; Nicolas Bonin; Vincent Pibarot
Journal:  Int Orthop       Date:  2018-02-22       Impact factor: 3.075

2.  Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

Authors:  Alexandre Terrier; Adeliya Latypova; Maika Guillemin; Valérie Parvex; Olivier Guyen
Journal:  Int Orthop       Date:  2017-01-09       Impact factor: 3.075

3.  Influence of the femoral offset on the muscles passive resistance in total hip arthroplasty.

Authors:  Stanisław Burzyński; Agnieszka Sabik; Wojciech Witkowski; Piotr Łuczkiewicz
Journal:  PLoS One       Date:  2021-05-04       Impact factor: 3.240

4.  The accuracy of restoration of femoral head centre of rotation in the anteroposterior plane after uncemented total hip arthroplasty : a CT-based study.

Authors:  Asim Rajpura; Soheil Ghane Asle; Tarik Ait Si Selmi; Tim Board
Journal:  Bone Joint Res       Date:  2022-03       Impact factor: 5.853

5.  Polyethylene wear of dual mobility cups: a comparative analysis based on patient-specific finite element modeling.

Authors:  Julien Wegrzyn; Alexander Antoniadis; Ehsan Sarshari; Matthieu Boubat; Alexandre Terrier
Journal:  Int Orthop       Date:  2022-01-12       Impact factor: 3.075

6.  Femoral Stress Changes after Total Hip Arthroplasty with the Ribbed Prosthesis: A Finite Element Analysis.

Authors:  Changqi Luo; Xiang-Dong Wu; Yifei Wan; Junyi Liao; Qiang Cheng; Mian Tian; Zhibiao Bai; Wei Huang
Journal:  Biomed Res Int       Date:  2020-03-23       Impact factor: 3.411