| Literature DB >> 26496894 |
Sigurlaug Benediktsdottir1, Torbjørn M Eggebø2,3, Kjell Å Salvesen4,5.
Abstract
BACKGROUND: To compare 2D transperineal ultrasound assessment of cervical dilatation with vaginal examination and to investigate intra-observer variability of the ultrasound method.Entities:
Mesh:
Year: 2015 PMID: 26496894 PMCID: PMC4619348 DOI: 10.1186/s12884-015-0704-z
Source DB: PubMed Journal: BMC Pregnancy Childbirth ISSN: 1471-2393 Impact factor: 3.007
Fig. 1Transperineal (2D) ultrasound measurement of cervical dilatation at (a) 4,3 cm and (b) 7,0 cm
Fig. 2Flow-chart illustrating the study population
Characteristics of the study population
| Characteristics |
|
|---|---|
| Mother | |
| Maternal age (years) | 30.5 (23–43) |
| Body mass index (kg/m2) | 24.3 (18–36) |
| Gestational age (weeks) | 40 (36–42) |
| Parity | 1 (0–5) |
| Labor | |
| Induction of labor | 23 (27) |
| Augmentation of labor | 56 (65) |
| Epidural analgesia | 38 (44) |
| Cesarean delivery | 7 (8) |
| Operative vaginal delivery | 13 (15) |
| Newborn | |
| Birth weight (g) | 3665 (2010–4780) |
Fig. 3Bland-Altman plot of intermethod agreement between digital examinations and ultrasound measurements of cervical dilatation. Mean difference and limits of agreement
Intermethod agreement between ultrasound examinations and digital palpations
| Cervix dilatation (cm) | Difference between the 2 methods (cm) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean | Median | Range | Inter-CC (95 % CI) | Mean | 95 % CI of mean | 1.96 SD | Lower limit | Upper limit | 95 % CI of lower limit | 95 % CI of upper limit | Range |
| 4.24 | 4.65 | 0.68 to 8.45 | 0.83 (0.72–0.90) | 0.91 | 0.47 to 1.34 | 3.25 | −2.34 | 4.16 | −3.07 to −1.61 | 3.43 to 4.89 | −3.2 to 6.17 |
Mean, median and range for cervix dilatation are calculated from the mean of the 2 methods
Inter-CC interclass correlation coefficient, SD standard deviation
Fig. 4Scatter plot illustrating the association between ultrasound measurements and digital examinations of cervical dilatation
Intraobserver repetability for ultrasound measurements of cervical dilatation
| Cervical dilatation (cm) | Difference between highest and lowest values (cm) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Mean | Median | Range | Intra-CC (95%CI) | Repeatability coefficient (cm) (95%CI) | Mean | Median | 10th centile | 90th centile | Range |
| 4.53 | 4.60 | 1.37–7.20 | 0.99 (0.97–0.99) | ±0.68 (0.45–0.91) | 0.38 | 0.30 | 0.10 | 0.70 | 0–1.0 |
Mean, median and range of ultrasound examinations of cervical dilatation are calculated from the mean of 3 measurements
Intra-CC intraclass correlation coefficient