Literature DB >> 12530614

Intrapartum sonography to determine fetal head position.

S Akmal1, E Tsoi, N Kametas, R Howard, K H Nicolaides.   

Abstract

OBJECTIVE: To investigate the accuracy of intrapartum transvaginal digital examination in defining the position of the fetal head. PATIENTS AND METHODS: In 496 singleton pregnancies in labor at term, the fetal head position was determined by routine transvaginal digital examination by the attending midwife or obstetrician. Immediately before or after the clinical examination, the fetal head position was determined using transabdominal ultrasound by an appropriately trained sonographer who was not aware of the clinical findings. The digital examination was considered to be correct if the fetal head position was within 45 degrees of the ultrasound finding. The accuracy of the digital examination was examined in relation to maternal characteristics and the progress of labor.
RESULTS: The position of the fetal head was determined by ultrasound examination in all 496 cases examined. Digital examination failed to define the fetal head position in 166 (33.5%) cases and, in 330 cases where the position was determined, the findings of the digital and sonographic examinations were in agreement in only 163 (49.4%) cases. The rate of correct identification of the fetal position by digital examination increased with cervical dilatation, from 20.5% at 3-4 cm to 44.2% at 8-10 cm, and was higher if the examination was carried out by an obstetrician than a midwife (50% versus 30%) and if there was absence rather than presence of caput (33% versus 25%).
CONCLUSIONS: Routine digital examination during labor fails to identify the correct fetal position in the majority of cases.

Entities:  

Mesh:

Year:  2002        PMID: 12530614     DOI: 10.1080/jmf.12.3.172.177

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  20 in total

Review 1.  The effectiveness of intrapartum  ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis.

Authors:  Yaw Amo Wiafe; Bill Whitehead; Heather Venables; Emmanuel Kweku Nakua
Journal:  Ultrasound       Date:  2016-10-06

2.  Dynamic Changes in the Myometrium during the Third Stage of Labor, Evaluated Using Two-Dimensional Ultrasound, in Women with Normal and Abnormal Third Stage of Labor and in Women with Obstetric Complications.

Authors:  Manasi Patwardhan; Edgar Hernandez-Andrade; Hyunyoung Ahn; Steven J Korzeniewski; Alyse Schwartz; Sonia S Hassan; Roberto Romero
Journal:  Gynecol Obstet Invest       Date:  2015-01-28       Impact factor: 2.031

Review 3.  Intrapartum sonographic assessment of labor.

Authors:  Uri Erlik; Igal Wolman
Journal:  J Obstet Gynaecol India       Date:  2013-10-09

4.  Intrapartum ultrasound use in clinical practice as a predictor of delivery mode during prolonged second stage of labor.

Authors:  Edi Vaisbuch; Roni Levy; Tamar Katzir; Yoav Brezinov; Ella Khairish; Shira Hadad
Journal:  Arch Gynecol Obstet       Date:  2022-05-16       Impact factor: 2.344

5.  Time to delivery based on sonographic assessment prior to forceps and vacuum.

Authors:  Sana Usman; Birgitte Kahrs; Helen Barton; Kjell Salvesen; Torbjorn Moe Eggebo; Christoph Lees
Journal:  Australas J Ultrasound Med       Date:  2019-01-21

6.  Sonographic evaluation in the second stage of labor to improve the assessment of labor progress and its outcome.

Authors:  Lami Yeo; Roberto Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2009-03       Impact factor: 7.299

7.  Study protocol. IDUS - Instrumental delivery & ultrasound: a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery.

Authors:  Deirdre J Murphy; Gerard Burke; Alan A Montgomery; Meenakshi Ramphul
Journal:  BMC Pregnancy Childbirth       Date:  2012-09-13       Impact factor: 3.007

8.  The Angle of Progression at Station 0 and in Magnetic Resonance and Transperineal Ultrasound Assessment.

Authors:  D Iliescu; S Tudorache; R Dragusin; O Carbunaru; C Patru; M Florea; I A Gheonea
Journal:  Case Rep Obstet Gynecol       Date:  2015-09-21

9.  Maternal positioning to correct occipito-posterior fetal position in labour: a randomised controlled trial.

Authors:  Marie-Julia Guittier; Véronique Othenin-Girard; Olivier Irion; Michel Boulvain
Journal:  BMC Pregnancy Childbirth       Date:  2014-02-24       Impact factor: 3.007

Review 10.  Intrapartum sonography - eccentricity or necessity?

Authors:  Marzena Dębska; Piotr Kretowicz; Romuald Dębski
Journal:  J Ultrason       Date:  2015-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.