Literature DB >> 26467552

Structural Mechanics Predictions Relating to Clinical Coronary Stent Fracture in a 5 Year Period in FDA MAUDE Database.

Kay D Everett1, Claire Conway2, Gerard J Desany3, Brian L Baker4, Gilwoo Choi5, Charles A Taylor6, Elazer R Edelman7,8.   

Abstract

Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006-2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.

Entities:  

Keywords:  Arterial deformation; Finite element analysis; Stent fracture

Mesh:

Year:  2015        PMID: 26467552      PMCID: PMC5082979          DOI: 10.1007/s10439-015-1476-3

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  40 in total

1.  Four-dimensional analysis of cyclic changes in coronary artery shape.

Authors:  Robert Liao; S-Y James Chen; John C Messenger; Bertron M Groves; J E B Burchenal; John D Carroll
Journal:  Catheter Cardiovasc Interv       Date:  2002-03       Impact factor: 2.692

2.  On high-cycle fatigue of 316L stents.

Authors:  Olga Barrera; Ahmed Makradi; Mohammed Abbadi; Mohamed Azaouzi; Salim Belouettar
Journal:  Comput Methods Biomech Biomed Engin       Date:  2012-05-16       Impact factor: 1.763

3.  An intriguing design concept to enhance the pulsatile fatigue life of self-expanding stents.

Authors:  Hao-Ming Hsiao; Ming-Ting Yin
Journal:  Biomed Microdevices       Date:  2014-02       Impact factor: 2.838

4.  Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation.

Authors:  Yasushi Ino; Yasuaki Toyoda; Atsushi Tanaka; Shuuta Ishii; Yoshio Kusuyama; Takashi Kubo; Shigeho Takarada; Hironori Kitabata; Takashi Tanimoto; Masato Mizukoshi; Toshio Imanishi; Takashi Akasaka
Journal:  Circ J       Date:  2009-08-28       Impact factor: 2.993

5.  Fatigue behaviour of Nitinol peripheral stents: the role of plaque shape studied with computational structural analyses.

Authors:  Elena Dordoni; Alessio Meoli; Wei Wu; Gabriele Dubini; Francesco Migliavacca; Giancarlo Pennati; Lorenza Petrini
Journal:  Med Eng Phys       Date:  2014-04-12       Impact factor: 2.242

6.  3D coronary reconstruction from routine single-plane coronary angiograms: clinical validation and quantitative analysis of the right coronary artery in 100 patients.

Authors:  J C Messenger; S Y Chen; J D Carroll; J E Burchenal; K Kioussopoulos; B M Groves
Journal:  Int J Card Imaging       Date:  2000-12

7.  Fatigue life assessment of cardiovascular balloon-expandable stents: a two-scale plasticity-damage model approach.

Authors:  H A F Argente dos Santos; F Auricchio; M Conti
Journal:  J Mech Behav Biomed Mater       Date:  2012-06-27

8.  A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation.

Authors:  Jeffrey J Popma; Klaus Tiroch; Alexandra Almonacid; Sidney Cohen; David E Kandzari; Martin B Leon
Journal:  Am J Cardiol       Date:  2009-04-01       Impact factor: 2.778

9.  Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry.

Authors:  Kyung Woo Park; Jin Joo Park; In-Ho Chae; Jae-Bin Seo; Han-Mo Yang; Hae-Young Lee; Hyun-Jae Kang; Young-Seok Cho; Tae-Jin Yeon; Woo-Young Chung; Bon-Kwon Koo; Dong-Ju Choi; Byung-Hee Oh; Young-Bae Park; Hyo-Soo Kim
Journal:  J Korean Med Sci       Date:  2010-12-22       Impact factor: 2.153

10.  Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.

Authors:  John F LaDisa; Lars E Olson; Hettrick A Douglas; David C Warltier; Judy R Kersten; Paul S Pagel
Journal:  Biomed Eng Online       Date:  2006-06-16       Impact factor: 2.819

View more
  4 in total

1.  Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015.

Authors:  Michael J Connor; Deborah C Marshall; Vitali Moiseenko; Kevin Moore; Laura Cervino; Todd Atwood; Parag Sanghvi; Arno J Mundt; Todd Pawlicki; Abram Recht; Jona A Hattangadi-Gluth
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-01-01       Impact factor: 7.038

2.  Nickel-Titanium peripheral stents: Which is the best criterion for the multi-axial fatigue strength assessment?

Authors:  Francesca Berti; Pei-Jiang Wang; Andrea Spagnoli; Giancarlo Pennati; Francesco Migliavacca; Elazer R Edelman; Lorenza Petrini
Journal:  J Mech Behav Biomed Mater       Date:  2020-10-18

Review 3.  Angiography-Based 4-Dimensional Superficial Wall Strain and Stress: A New Diagnostic Tool in the Catheterization Laboratory.

Authors:  Xinlei Wu; Masafumi Ono; Hideyuki Kawashima; Eric K W Poon; Ryo Torii; Atif Shahzad; Chao Gao; Rutao Wang; Peter Barlis; Clemens von Birgelen; Johan H C Reiber; Christos V Bourantas; Shengxian Tu; William Wijns; Patrick W Serruys; Yoshinobu Onuma
Journal:  Front Cardiovasc Med       Date:  2021-06-18

4.  Sex differences in the outcomes of stent implantation in mini-swine model.

Authors:  Mie Kunio; Gee Wong; Peter M Markham; Elazer R Edelman
Journal:  PLoS One       Date:  2018-01-29       Impact factor: 3.240

  4 in total