Fatigue life assessment of cardiovascular balloon-expandable stents: a two-scale plasticity-damage model approach.

H A F Argente dos Santos1, F Auricchio, M Conti.   

Abstract

Cardiovascular disease has become a major global health care problem in the present decade. To tackle this problem, the use of cardiovascular stents has been considered a promising and effective approach. Numerical simulations to evaluate the in vivo behavior of stents are becoming more and more important to assess potential failures. As the material failure of a stent device has been often associated with fatigue issues, as a result of the high number of cyclic loads these devices are subjected to in vivo, numerical approaches for fatigue life assessment of stents has gained special interest in the engineering community. Numerical fatigue predictions can be used to modify the design and prevent failure, without making and testing numerous physical devices, thus preventing from undesired fatigue failures. This work presents a fatigue life numerical method for the analysis of cardiovascular balloon-expandable stainless steel stents. The method is based on a two-scale continuum damage mechanics model in which both plasticity and damage mechanisms are assumed to take place at a scale smaller than the scale of the representative volume element. The fatigue failure criterion is based on the Soderberg relation. The method is applied to the fatigue life assessment of both PalmazShatz and Cypher stent designs. Validation of the method is performed through comparison of the obtained numerical results with some experimental results available for the PalmazShatz stent design. The present study gives also possible directions for future research developments in the framework of the numerical fatigue life assessment of real balloon-expandable stents.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23032428     DOI: 10.1016/j.jmbbm.2012.06.011

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

1.  Structural Mechanics Predictions Relating to Clinical Coronary Stent Fracture in a 5 Year Period in FDA MAUDE Database.

Authors:  Kay D Everett; Claire Conway; Gerard J Desany; Brian L Baker; Gilwoo Choi; Charles A Taylor; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2015-10-14       Impact factor: 3.934

2.  Mechanical response of cardiovascular stents under vascular dynamic bending.

Authors:  Jiang Xu; Jie Yang; Nan Huang; Christopher Uhl; Yihua Zhou; Yaling Liu
Journal:  Biomed Eng Online       Date:  2016-02-20       Impact factor: 2.819

Review 3.  A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.

Authors:  Mehdi Jafary-Zadeh; Gideon Praveen Kumar; Paulo Sergio Branicio; Mohsen Seifi; John J Lewandowski; Fangsen Cui
Journal:  J Funct Biomater       Date:  2018-02-27