Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions.

K Ohara1, K Doi, C E Metz, M L Giger.   

Abstract

We investigated the effects of structured background noise on the detectability of stenotic lesions. Digital subtraction angiographic (DSA) images of stenotic blood vessels were simulated and superimposed onto uniform noise samples. Eighteen-alternative forced choice (18-AFC) experiments were employed to determine the detectability of the stenotic lesion in the structured-noise background of a blood vessel. In this study, the dependence of detectability on lesion size, vessel size, and incident x-ray exposure was examined. Our results indicate that the presence of structured noise in an image will reduce the detectability of a lesion. However, the relative performance of an observer when the lesion size and incident exposure were varied was the same with and without the presence of the structured background. Thus, conclusions obtained previously with regard to changes in the detectability of a lesion in the presence of uniform background noise can be applied directly to conditions in which simple structured anatomic background is present.

Entities:  

Mesh:

Year:  1989        PMID: 2646515     DOI: 10.1118/1.596391

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Sandra M Waldrop; Carl J D'Orsi
Journal:  J Digit Imaging       Date:  2004-03       Impact factor: 4.056

2.  Detection of simulated microcalcifications in a phantom with digital mammography: effect of pixel size.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Ioannis Sechopoulos; Carl J D'Orsi
Journal:  Radiology       Date:  2007-05-23       Impact factor: 11.105

3.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

Authors:  Chao-Jen Lai; Chris C Shaw; Lingyun Chen; Mustafa C Altunbas; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman; Shu-Ju Tu
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  Contrast, noise, and blur affect performance and appreciation of digital radiographs.

Authors:  I M van Overveld
Journal:  J Digit Imaging       Date:  1995-11       Impact factor: 4.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.