Literature DB >> 22484900

Dimensional accuracy and detail reproduction of two hydrophilic vinyl polysiloxane impression materials tested under different conditions.

Preeti Agarwal Katyayan1, Natarajan Kalavathy, Manish Katyayan.   

Abstract

BACKGROUND AND OBJECTIVES: A limitation of vinyl polysiloxane (VPS) impression materials is hydrophobicity, and manufacturers have added surfactants and labeled these new products as "hydrophilic." The purpose of this investigation was to evaluate and compare the dimensional accuracy and surface detail reproduction of two hydrophilic VPS impression materials under dry, moist, and wet conditions.
MATERIALS AND METHODS: Ten impressions were made under dry, moist, and wet conditions respectively, with monophase, and regular body VPS impression material using a stainless steel metal die similar to that described in American Dental Association (ADA) specification 19, with lines scribed on it. Dimensional accuracy was measured by comparing the average length of the middle horizontal line in each impression to the same line on the metal die, by using a measuring microscope. The surface detail was evaluated. A one-way analysis of variance and Student t-test were used to compare mean dimensional changes (α = 0.05).
RESULTS: Conditions (dry, moist, and wet) did not cause significant adverse effects on the dimensional accuracy of either material. The mean dimensional changes were 0.00084% (+0.00041%) for monophase and 0.00119% (+0.00033%) for regular body. Monophase material was satisfactory in detail reproduction 100% of the time in dry conditions, 90% in moist, and only 20% in wet conditions. The regular body showed 100% satisfactory impressions in dry, 80% in moist, and 10% in wet conditions. With the additional smooth surface evaluation, only under dry conditions impressions with clinically acceptable surface quality were produced.
CONCLUSIONS: Dimensional changes for both materials were well within ADA standards of minimal shrinkage value of 0.5%.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22484900     DOI: 10.4103/0970-9290.94697

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  4 in total

1.  A Comparative Evaluation of Dimensional Accuracy and Surface Detail Reproduction of Four Hydrophilic Vinyl Polysiloxane Impression Materials Tested Under Dry, Moist, and Wet Conditions-An In Vitro Study.

Authors:  Rahul Nagrath; Manesh Lahori; Manjari Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2014-05-11

2.  Evaluation of setting time, tear strength, dimensional stability and antimicrobial property of silver and titanium nanoparticles incorporated elastomeric impression material.

Authors:  Kapoor Abhijeet; J Brintha Jei; K Murugesan; B Muthukumar
Journal:  J Oral Biol Craniofac Res       Date:  2022-07-19

3.  Digital assessment of properties of the three different generations of dental elastomeric impression materials.

Authors:  Lamia Singer; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2022-09-05       Impact factor: 3.747

4.  Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

Authors:  Suresh S Kamble; Rakshit Vijay Khandeparker; P Somasundaram; Shweta Raghav; Rashmi P Babaji; T Joju Varghese
Journal:  J Int Oral Health       Date:  2015-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.