RATIONALE AND
OBJECTIVES: To assess image quality, radiation dose, and diagnostic accuracy of 70-kVp high-pitch computed tomography pulmonary angiography (CTPA) using 40 mL contrast agent and sinogram affirmed iterative reconstruction (SAFIRE) compared to 100-kVp CTPA using 60 mL contrast agent and filtered back projection.
MATERIALS AND METHODS: Eighty patients underwent CTPA at either 70 kVp (group A, n = 40; 3.2 pitch, 40 mL contrast medium, and SAFIRE) or 100 kVp (group B, n = 40; 1.2 pitch, 60 mL contrast medium, and filtered back projection). Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was evaluated using a five-grade scale, and diagnostic accuracy was assessed. Radiation doses were compared.
RESULTS: Computed tomography values, signal-to-noise ratio, and contrast-to-noise ratio of pulmonary arteries were higher in group A compared to group B (all P < 0.001). Subjective image quality showed no difference between the two groups (P = 0.559) with good interobserver agreement (κ = 0.647). No difference was found regarding diagnostic accuracy between the two groups (P > 0.05). The effective dose for group A was lower by 80% compared to group B (P < 0.001).
CONCLUSIONS: 70-kVp high-pitch CTPA with reduced contrast media and SAFIRE provides comparable image quality and substantial radiation dose savings compared to a routine CTPA protocol.
Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Computed tomography pulmonary angiography; Contrast material; Iterative reconstruction; Pulmonary embolism; Radiation dose

Mesh:

Substances:

Year:  2015        PMID: 26432073     DOI: 10.1016/j.acra.2015.08.026

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  14 in total

1.  Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Authors:  Prabhakar Rajiah; Leslie Ciancibello; Ronald Novak; Jennifer Sposato; Luis Landeras; Robert Gilkeson
Journal:  Diagn Interv Radiol       Date:  2019-05       Impact factor: 2.630

Review 2.  Dual-energy CT in pulmonary vascular disease.

Authors:  Ioannis Vlahos; Megan C Jacobsen; Myrna C Godoy; Konstantinos Stefanidis; Rick R Layman
Journal:  Br J Radiol       Date:  2021-09-24       Impact factor: 3.039

3.  CT pulmonary angiography: simultaneous low-pitch dual-source acquisition mode with 70 kVp and 40 ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection.

Authors:  Johannes Boos; Patric Kröpil; Rotem S Lanzman; Joel Aissa; Christoph Schleich; Philipp Heusch; Lino M Sawicki; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

4.  Optimization of computed tomography pulmonary angiography protocols using 3D printed model with simulation of pulmonary embolism.

Authors:  Sultan Aldosari; Shirley Jansen; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-01

5.  Patient-specific 3D printed pulmonary artery model with simulation of peripheral pulmonary embolism for developing optimal computed tomography pulmonary angiography protocols.

Authors:  Sultan Aldosari; Shirley Jansen; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-01

6.  Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging.

Authors:  Saravanabavaan Suntharalingam; Christian Mikat; Elena Stenzel; Youssef Erfanian; Axel Wetter; Thomas Schlosser; Michael Forsting; Kai Nassenstein
Journal:  PLoS One       Date:  2017-10-18       Impact factor: 3.240

7.  Use of pulmonary CT angiography with low tube voltage and low-iodine-concentration contrast agent to diagnose pulmonary embolism.

Authors:  Xuemei Hu; Liya Ma; Jinhua Zhang; Zhen Li; Yaqi Shen; Daoyu Hu
Journal:  Sci Rep       Date:  2017-10-16       Impact factor: 4.379

8.  Minimizing contrast media dose in CT pulmonary angiography with high-pitch technique.

Authors:  Hanan Alobeidi; Muhammed Alshamari; Jonas Widell; Tomas Eriksson; Mats Lidén
Journal:  Br J Radiol       Date:  2020-05-21       Impact factor: 3.039

9.  Computed Tomography Pulmonary Angiography during Pregnancy: Radiation Dose of Commonly Used Protocols and the Effect of Scan Length Optimization.

Authors:  Babs M F Hendriks; Roald S Schnerr; Gianluca Milanese; Cécile R L P N Jeukens; Sandra Niesen; Nienke G Eijsvoogel; Joachim E Wildberger; Marco Das
Journal:  Korean J Radiol       Date:  2019-02       Impact factor: 3.500

10.  CT pulmonary angiography in patients with acute or chronic renal insufficiency: Evaluation of a low dose contrast material protocol.

Authors:  Mathias Meyer; Holger Haubenreisser; Christoph Schabel; Christianne Leidecker; Bernhard Schmidt; Stefan O Schoenberg; Thomas Henzler
Journal:  Sci Rep       Date:  2018-01-31       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.