Literature DB >> 26418696

Fiber-optic Monitoring of Spinal Cord Hemodynamics in Experimental Aortic Occlusion.

Angela S Kogler1, Thomas V Bilfinger, Robert M Galler, Rickson C Mesquita, Michael Cutrone, Steven S Schenkel, Arjun G Yodh, Thomas F Floyd.   

Abstract

BACKGROUND: Spinal cord ischemia occurs frequently during thoracic aneurysm repair. Current methods based on electrophysiology techniques to detect ischemia are indirect, non-specific, and temporally slow. In this article, the authors report the testing of a spinal cord blood flow and oxygenation monitor, based on diffuse correlation and optical spectroscopies, during aortic occlusion in a sheep model.
METHODS: Testing was carried out in 16 Dorset sheep. Sensitivity in detecting spinal cord blood flow and oxygenation changes during aortic occlusion, pharmacologically induced hypotension and hypertension, and physiologically induced hypoxia/hypercarbia was assessed. Accuracy of the diffuse correlation spectroscopy measurements was determined via comparison with microsphere blood flow measurements. Precision was assessed through repeated measurements in response to pharmacologic interventions.
RESULTS: The fiber-optic probe can be placed percutaneously and is capable of continuously measuring spinal cord blood flow and oxygenation preoperatively, intraoperatively, and postoperatively. The device is sensitive to spinal cord blood flow and oxygenation changes associated with aortic occlusion, immediately detecting a decrease in blood flow (-65 ± 32%; n = 32) and blood oxygenation (-17 ± 13%, n = 11) in 100% of trials. Comparison of spinal cord blood flow measurements by the device with microsphere measurements led to a correlation of R = 0.49, P < 0.01, and the within-sheep coefficient of variation was 9.69%. Finally, diffuse correlation spectroscopy is temporally more sensitive to ischemic interventions than motor-evoked potentials.
CONCLUSION: The first-generation spinal fiber-optic monitoring device offers a novel and potentially important step forward in the monitoring of spinal cord ischemia.

Entities:  

Mesh:

Year:  2015        PMID: 26418696      PMCID: PMC4679520          DOI: 10.1097/ALN.0000000000000883

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  35 in total

1.  Scattering and Imaging with Diffusing Temporal Field Correlations.

Authors: 
Journal:  Phys Rev Lett       Date:  1995-08-28       Impact factor: 9.161

2.  Evidence-based guideline update: intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials*.

Authors:  Marc R Nuwer; Ronald G Emerson; Gloria Galloway; Alan D Legatt; Jaime Lopez; Robert Minahan; Thoru Yamada; Douglas S Goodin; Carmel Armon; Vinay Chaudhry; Gary S Gronseth; Cynthia L Harden
Journal:  J Clin Neurophysiol       Date:  2012-02       Impact factor: 2.177

3.  Absorption spectroscopy in tissue-simulating materials: a theoretical and experimental study of photon paths.

Authors:  M S Patterson; S Andersson-Engels; B C Wilson; E K Osei
Journal:  Appl Opt       Date:  1995-01-01       Impact factor: 1.980

4.  Spinal cord blood supply in patients with thoracoabdominal aortic aneurysms.

Authors:  Michael J Jacobs; Bas A de Mol; Ted Elenbaas; Werner H Mess; Cor J Kalkman; Geert W Schurink; Bas Mochtar
Journal:  J Vasc Surg       Date:  2002-01       Impact factor: 4.268

5.  Analysis of motor and somatosensory evoked potentials during thoracic and thoracoabdominal aortic aneurysm repair.

Authors:  Kourosh Keyhani; Charles C Miller; Anthony L Estrera; Tara Wegryn; Roy Sheinbaum; Hazim J Safi
Journal:  J Vasc Surg       Date:  2008-10-01       Impact factor: 4.268

Review 6.  Blood supply and vascular reactivity of the spinal cord under normal and pathological conditions.

Authors:  Nikolay L Martirosyan; Jeanne S Feuerstein; Nicholas Theodore; Daniel D Cavalcanti; Robert F Spetzler; Mark C Preul
Journal:  J Neurosurg Spine       Date:  2011-06-10

7.  Diffuse optics for monitoring brain hemodynamics.

Authors:  Arjun G Yodh
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

8.  Validation of diffuse correlation spectroscopy for muscle blood flow with concurrent arterial spin labeled perfusion MRI.

Authors:  Guoqiang Yu; Thomas F Floyd; Turgut Durduran; Chao Zhou; Jiongjiong Wang; John A Detre; Arjun G Yodh
Journal:  Opt Express       Date:  2007-02-05       Impact factor: 3.894

9.  Direct measurement of tissue blood flow and metabolism with diffuse optics.

Authors:  Rickson C Mesquita; Turgut Durduran; Guoqiang Yu; Erin M Buckley; Meeri N Kim; Chao Zhou; Regine Choe; Ulas Sunar; Arjun G Yodh
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.019

10.  Why are sensory axons more vulnerable for ischemia than motor axons?

Authors:  Jeannette Hofmeijer; Hessel Franssen; Leonard J van Schelven; Michel J A M van Putten
Journal:  PLoS One       Date:  2013-06-20       Impact factor: 3.240

View more
  10 in total

1.  Validation of diffuse correlation spectroscopy sensitivity to nicotinamide-induced blood flow elevation in the murine hindlimb using the fluorescent microsphere technique.

Authors:  Ashley R Proctor; Gabriel A Ramirez; Songfeng Han; Ziping Liu; Tracy M Bubel; Regine Choe
Journal:  J Biomed Opt       Date:  2018-03       Impact factor: 3.170

2.  Multi-Site Optical Monitoring of Spinal Cord Ischemia during Spine Distraction.

Authors:  David R Busch; Wei Lin; Chunyu Cai; Alissa Cutrone; Jakub Tatka; Brandon J Kovarovic; Arjun G Yodh; Thomas F Floyd; James Barsi
Journal:  J Neurotrauma       Date:  2020-07-20       Impact factor: 5.269

3.  Transcutaneous contrast-enhanced ultrasound imaging of the posttraumatic spinal cord.

Authors:  Zin Z Khaing; Lindsay N Cates; Jeffrey E Hyde; Ryan Hammond; Matthew Bruce; Christoph P Hofstetter
Journal:  Spinal Cord       Date:  2020-01-21       Impact factor: 2.772

4.  Diffuse Correlation Spectroscopy Analysis Implemented on a Field Programmable Gate Array.

Authors:  Wei Lin; David R Busch; Chia Chieh Goh; James Barsi; Thomas F Floyd
Journal:  IEEE Access       Date:  2019-08-28       Impact factor: 3.367

Review 5.  Monitoring spinal cord hemodynamics and tissue oxygenation: a review of the literature with special focus on the near-infrared spectroscopy technique.

Authors:  Tahereh Rashnavadi; Andrew Macnab; Amanda Cheung; Armita Shadgan; Brian K Kwon; Babak Shadgan
Journal:  Spinal Cord       Date:  2019-06-04       Impact factor: 2.772

6.  Optical imaging and spectroscopy for the study of the human brain: status report.

Authors:  Hasan Ayaz; Wesley B Baker; Giles Blaney; David A Boas; Heather Bortfeld; Kenneth Brady; Joshua Brake; Sabrina Brigadoi; Erin M Buckley; Stefan A Carp; Robert J Cooper; Kyle R Cowdrick; Joseph P Culver; Ippeita Dan; Hamid Dehghani; Anna Devor; Turgut Durduran; Adam T Eggebrecht; Lauren L Emberson; Qianqian Fang; Sergio Fantini; Maria Angela Franceschini; Jonas B Fischer; Judit Gervain; Joy Hirsch; Keum-Shik Hong; Roarke Horstmeyer; Jana M Kainerstorfer; Tiffany S Ko; Daniel J Licht; Adam Liebert; Robert Luke; Jennifer M Lynch; Jaume Mesquida; Rickson C Mesquita; Noman Naseer; Sergio L Novi; Felipe Orihuela-Espina; Thomas D O'Sullivan; Darcy S Peterka; Antonio Pifferi; Luca Pollonini; Angelo Sassaroli; João Ricardo Sato; Felix Scholkmann; Lorenzo Spinelli; Vivek J Srinivasan; Keith St Lawrence; Ilias Tachtsidis; Yunjie Tong; Alessandro Torricelli; Tara Urner; Heidrun Wabnitz; Martin Wolf; Ursula Wolf; Shiqi Xu; Changhuei Yang; Arjun G Yodh; Meryem A Yücel; Wenjun Zhou
Journal:  Neurophotonics       Date:  2022-08-30       Impact factor: 4.212

7.  Intraoperative Optical Monitoring of Spinal Cord Hemodynamics Using Multiwavelength Imaging System.

Authors:  Nicolas Mainard; Olivier Tsiakaka; Songlin Li; Julien Denoulet; Karim Messaoudene; Raphael Vialle; Sylvain Feruglio
Journal:  Sensors (Basel)       Date:  2022-05-19       Impact factor: 3.847

8.  Spinal cord autoregulation using near-infrared spectroscopy under normal, hypovolemic, and post-fluid resuscitation conditions in a swine model: a comparison with cerebral autoregulation.

Authors:  Tadayoshi Kurita; Shingo Kawashima; Koji Morita; Yoshiki Nakajima
Journal:  J Intensive Care       Date:  2020-04-15

9.  Towards rapid intraoperative axial localization of spinal cord ischemia with epidural diffuse correlation monitoring.

Authors:  David R Busch; Wei Lin; Chia Chieh Goh; Feng Gao; Nicholas Larson; Joseph Wahl; Thomas V Bilfinger; Arjun G Yodh; Thomas F Floyd
Journal:  PLoS One       Date:  2021-05-10       Impact factor: 3.240

10.  Dual-Polarization Bandwidth-Bridged Bandpass Sampling Fourier Transform Spectrometer from Visible to Near-Infrared on a Silicon Nitride Platform.

Authors:  Kyoung Min Yoo; Ray T Chen
Journal:  ACS Photonics       Date:  2022-07-21       Impact factor: 7.077

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.