Literature DB >> 26310613

Resonance artefacts in modern pressure monitoring systems.

L Bocchi1, S Romagnoli2.   

Abstract

Resonance in pressure monitoring catheters is a well-known problem which was studied several years ago. Current piezoelectric devices have mechanical properties providing a resonance frequency and damping factor that theoretically assure resonance-free data. However, in particular cases, the coupling between the device, the catheter, and the vascular compliance of the patient could introduce artefacts in clinical settings leading to wrong pressure waveforms and values displayed in the monitor. In this research work we study a laboratory model of a clinical setting to evaluate in which cases the compound (catheter and device) could cause resonances in an unacceptable range. The classical pop-test is expanded for analysing the effect of the catheter. Results indicate that the presence of different catheters may alter significantly the acquired signal, up to an unacceptable level. Particular care should be used in the selection of the appropriate catheter. In particular, smaller diameters introduce higher damping coefficient that could help in avoiding undesired oscillations.

Entities:  

Keywords:  Invasive pressure monitoring; Physical model; Underdamping

Mesh:

Year:  2015        PMID: 26310613     DOI: 10.1007/s10877-015-9760-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  14 in total

Review 1.  Understanding natural frequency and damping and how they relate to the measurement of blood pressure.

Authors:  B Kleinman
Journal:  J Clin Monit       Date:  1989-04

2.  Results of a survey of blood pressure monitoring by intensivists in critically ill patients: a preliminary study.

Authors:  Arjun Chatterjee; Kirk DePriest; Russell Blair; David Bowton; Robert Chin
Journal:  Crit Care Med       Date:  2010-12       Impact factor: 7.598

3.  Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.

Authors:  Stefano Romagnoli; Salvatore Mario Romano; Sergio Bevilacqua; Chiara Lazzeri; Gian Franco Gensini; Carlo Pratesi; Diego Quattrone; Daniele Dini; Angelo Raffaele De Gaudio
Journal:  J Crit Care       Date:  2010-10-30       Impact factor: 3.425

Review 4.  Critical care in the emergency department: monitoring the critically ill patient.

Authors:  F J Andrews; J P Nolan
Journal:  Emerg Med J       Date:  2006-07       Impact factor: 2.740

5.  Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients.

Authors:  Andreas Bur; Harald Herkner; Marianne Vlcek; Christian Woisetschläger; Ulla Derhaschnig; Georg Delle Karth; Anton N Laggner; Michael M Hirschl
Journal:  Crit Care Med       Date:  2003-03       Impact factor: 7.598

6.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

7.  Measurement of blood pressure.

Authors:  Bernd Saugel; Ron Dueck; Julia Y Wagner
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-06

8.  Methods of blood pressure measurement in the ICU.

Authors:  Li-wei H Lehman; Mohammed Saeed; Daniel Talmor; Roger Mark; Atul Malhotra
Journal:  Crit Care Med       Date:  2013-01       Impact factor: 7.598

Review 9.  Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12.

Authors:  Jean-Louis Vincent; Paolo Pelosi; Rupert Pearse; Didier Payen; Azriel Perel; Andreas Hoeft; Stefano Romagnoli; V Marco Ranieri; Carole Ichai; Patrice Forget; Giorgio Della Rocca; Andrew Rhodes
Journal:  Crit Care       Date:  2015-05-08       Impact factor: 9.097

10.  Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study.

Authors:  Stefano Romagnoli; Zaccaria Ricci; Diego Quattrone; Lorenzo Tofani; Omar Tujjar; Gianluca Villa; Salvatore M Romano; A Raffaele De Gaudio
Journal:  Crit Care       Date:  2014-11-30       Impact factor: 9.097

View more
  3 in total

Review 1.  Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A Critchley; Steffen Rex; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

2.  Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial.

Authors:  Hyongmin Oh; Suk Hyung Choe; Yoon Jung Kim; Hyun-Kyu Yoon; Hyung-Chul Lee; Hee-Pyoung Park
Journal:  J Clin Monit Comput       Date:  2021-02-01       Impact factor: 2.502

Review 3.  How to measure blood pressure using an arterial catheter: a systematic 5-step approach.

Authors:  Bernd Saugel; Karim Kouz; Agnes S Meidert; Leonie Schulte-Uentrop; Stefano Romagnoli
Journal:  Crit Care       Date:  2020-04-24       Impact factor: 9.097

  3 in total