Literature DB >> 25480763

Measurement of blood pressure.

Bernd Saugel1, Ron Dueck2, Julia Y Wagner3.   

Abstract

Blood pressure is overwhelmingly the most commonly measured parameter for the assessment of haemodynamic stability. In clinical routine in the operating theatre and in the intensive care unit, blood pressure measurements are usually obtained intermittently and non-invasively using oscillometry (upper-arm cuff method) or continuously and invasively with an arterial catheter. However, both the oscillometric method and arterial catheter-derived blood pressure measurements have potential limitations. A basic technical understanding of these methods is crucial in order to avoid unreliable blood pressure measurements and consequential treatment errors. In the recent years, technologies for continuous non-invasive blood pressure recording such as the volume clamp method or radial artery applanation tonometry have been developed and validated. The question in which patient groups and clinical settings these technologies should be applied to improve patient safety or outcome has not been definitively answered. In critically ill patients and high-risk surgery patients, further improvement of these technologies is needed before they can be recommended for routine clinical use.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  arterial catheter; monitoring; non-invasive; oscillometry; radial artery applanation tonometry; tonometry; volume clamp method

Mesh:

Year:  2014        PMID: 25480763     DOI: 10.1016/j.bpa.2014.08.001

Source DB:  PubMed          Journal:  Best Pract Res Clin Anaesthesiol        ISSN: 1521-6896


  29 in total

1.  Resonance artefacts in modern pressure monitoring systems.

Authors:  L Bocchi; S Romagnoli
Journal:  J Clin Monit Comput       Date:  2015-08-27       Impact factor: 2.502

Review 2.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

3.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Authors:  Julia Y Wagner; Ileana Negulescu; Miriam Schöfthaler; Alexander Hapfelmeier; Agnes S Meidert; Wolfgang Huber; Roland M Schmid; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-03-01       Impact factor: 2.502

4.  [Principles and pitfalls of arterial blood pressure measurement].

Authors:  A S Meidert; J Briegel; B Saugel
Journal:  Anaesthesist       Date:  2019-09       Impact factor: 1.041

Review 5.  Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A Critchley; Steffen Rex; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

6.  Less invasive hemodynamic monitoring in critically ill patients.

Authors:  Jean-Louis Teboul; Bernd Saugel; Maurizio Cecconi; Daniel De Backer; Christoph K Hofer; Xavier Monnet; Azriel Perel; Michael R Pinsky; Daniel A Reuter; Andrew Rhodes; Pierre Squara; Jean-Louis Vincent; Thomas W Scheeren
Journal:  Intensive Care Med       Date:  2016-05-07       Impact factor: 17.440

7.  Innovative noninvasive hemodynamic monitoring: curb your enthusiasm after initial validation studies and evaluate the technologies' clinical applicability.

Authors:  Bernd Saugel; Julia Y Wagner
Journal:  J Clin Monit Comput       Date:  2016-02-24       Impact factor: 2.502

8.  Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.

Authors:  Jing Sun; Hanjian Chen; Jun Zheng; Bin Mao; Shengmei Zhu; Jingyi Feng
Journal:  J Clin Monit Comput       Date:  2016-12-20       Impact factor: 2.502

9.  A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.

Authors:  Sándor Földi; Tamás Horváth; Flóra Zieger; Péter Sótonyi; György Cserey
Journal:  J Clin Monit Comput       Date:  2017-10-04       Impact factor: 2.502

Review 10.  Journal of Clinical Monitoring and Computing 2017 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A H Critchley; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2018-02-26       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.