Literature DB >> 17654891

Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT.

Jonathon A Nye1, Fabio Esteves, John R Votaw.   

Abstract

The introduction of positron emission/computed tomography (PET/CT) systems coupled with multidetector CT arrays has greatly increased the amount of clinical information in myocardial perfusion studies. The CT acquisition serves the dual role of providing high spatial anatomical detail and attenuation correction for PET. However, the differences between the interaction of respiratory and cardiac cycles in the CT and PET acquisitions presents a challenge when using the CT to determine PET attenuation correction. Three CT attenuation correction protocols were tested for their ability to produce accurate emission images: gated, a step mode acquisition covering the diastolic heart phase; normal, a high-pitch helical CT; and slow, a low-pitch, low-temporal-resolution helical CT. The amount of cardiac tissue in the emission image that overlaid lung tissue in the transmission image was used as the measure of mismatch between acquisitions. Phantom studies simulating misalignment of the heart between the transmission and emission sequences were used to correlate the amount of mismatch with the artificial defect changes in the emission image. Consecutive patients were studied prospectively with either paired gated (diastolic phase, 120 kVp, 280 mA, 2.6 s) and slow CT (0.562:1 pitch, 120 kVp, Auto-mA, 16 s) or paired normal (0.938:1 pitch, 120 kVp, Auto-mA, 4.8 s) and slow CT protocols, prior to a Rb-82 perfusion study. To determine the amount of mismatch, the transmission and emission images were converted to binary representations of attenuating tissue and cardiac tissue and overlaid using their native registration. The number of cardiac tissue pixels from the emission image present in the CT lung field yielded the magnitude of misalignment represented in terms of volume, of where a small volume indicates better registration. Acquiring a slow CT improved registration between the transmission and emission acquisitions compared to the gated and normal CT protocols. The volume of PET cardiac tissue in the CT lung field was significantly lower (p < 0.03) for the slow CT protocol in both the rest and stress emission studies. Phantom studies showed that an overlaying volume greater than 2.6 mL would produce significant artificial defects as determined by a quantitative software package that employs a normal database. The percentage of patient studies with overlaying volume greater than 2.6 mL was reduced from 71% with the normal CT protocol to 28% with the slow CT protocol. The remaining 28% exhibited artifacts consistent with heart drift and patient motion that could not be corrected by adjusting the CT acquisition protocol. The low pitch of the slow CT protocol provided the best match to the emission study and is recommended for attenuation correction in cardiac PET/CT studies. Further reduction in artifacts arising from cardiac drift is required and warrants an image registration solution.

Entities:  

Mesh:

Year:  2007        PMID: 17654891     DOI: 10.1118/1.2731033

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts.

Authors:  L Presotto; E Busnardo; D Perani; L Gianolli; M C Gilardi; V Bettinardi
Journal:  J Nucl Cardiol       Date:  2015-08-15       Impact factor: 5.952

2.  Investigation of emission-transmission misalignment artifacts on rubidium-82 cardiac PET with adenosine pharmacologic stress.

Authors:  David M Schuster; Raghuveer K Halkar; Fabio P Esteves; Ernest V Garcia; C David Cooke; Mushabbar A Syed; F DuBois Bowman; John R Votaw
Journal:  Mol Imaging Biol       Date:  2008-05-03       Impact factor: 3.488

Review 3.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

Review 4.  Importance of quantification for the analysis of PET data in oncology: review of current methods and trends for the future.

Authors:  Giampaolo Tomasi; Federico Turkheimer; Eric Aboagye
Journal:  Mol Imaging Biol       Date:  2012-04       Impact factor: 3.488

5.  Techniques for respiration-induced artifacts reductions in thoracic PET/CT.

Authors:  Tao Sun; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2012-03

Review 6.  Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET.

Authors:  Marina Piccinelli; John R Votaw; Ernest V Garcia
Journal:  Curr Cardiol Rep       Date:  2018-03-24       Impact factor: 2.931

7.  Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT.

Authors:  Fabio P Esteves; Jonathan A Nye; Akbar Khan; Russell D Folks; Raghuveer K Halkar; Ernest V Garcia; David M Schuster; Stamatios Lerakis; Paolo Raggi; John R Votaw
Journal:  J Nucl Cardiol       Date:  2009-11-24       Impact factor: 5.952

8.  Effect of Non-Alignment/Alignment of Attenuation Map Without/With Emission Motion Correction in Cardiac SPECT/CT.

Authors:  Joyoni Dey; W Paul Segars; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2015-07-23       Impact factor: 1.679

9.  Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography.

Authors:  Cesar A Santana; Ernest V Garcia; Tracy L Faber; Gopi K R Sirineni; Fabio P Esteves; Rupan Sanyal; Raghuveer Halkar; Mario Ornelas; Liudmila Verdes; Stamatios Lerakis; Julie J Ramos; Santiago Aguadé-Bruix; Hugo Cuéllar; Jaume Candell-Riera; Paolo Raggi
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952

Review 10.  Introduction to the analysis of PET data in oncology.

Authors:  Giampaolo Tomasi; Eric O Aboagye
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-02-27       Impact factor: 2.745

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.