Reproducibility of pallor measurements with the optic nerve head analyzer.

K N Miller1, M B Shields, A R Ollie.   

Abstract

One eye each of ten healthy volunteers was tested with the Rodenstock Optic Nerve Head Analyzer on ten separate occasions. A color-coded pallor map was developed for each examination. A color transparency of each pallor map was then obtained from the television monitor of the Optic Nerve Head Analyzer, using a camera mounted on a tripod at a fixed distance from the screen. A color-coded zone within the center of the disc was chosen for each set of ten studies, and the area of this zone was measured by boundary analysis with another computerized image analyzer, the Oasys Image Processor. There was wide intrasubject variation in all ten volunteers, suggesting that the pallor map generated by the Optic Nerve Head Analyzer, when used in the manner described in this paper, is not adequate for following subtle changes in optic nerve head pallor.

Mesh:

Year:  1989        PMID: 2625213     DOI: 10.1007/bf02169452

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  7 in total

1.  Reproducibility of computerized pallor measurements obtained with the Rodenstock Disk Analyzer.

Authors:  F S Mikelberg; G R Douglas; S M Drance; M Schulzer; K Wijsman
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1988       Impact factor: 3.117

2.  Videographic quantification of optic disc pallor.

Authors:  J M Miller; J Caprioli
Journal:  Invest Ophthalmol Vis Sci       Date:  1988-02       Impact factor: 4.799

3.  Reproducibility of topographic measurements with the optic nerve head analyzer.

Authors:  M B Shields; J F Martone; A R Shelton; A R Ollie; J MacMillan
Journal:  Am J Ophthalmol       Date:  1987-12-15       Impact factor: 5.258

4.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images.

Authors:  J Caprioli; U Klingbeil; M Sears; B Pope
Journal:  Arch Ophthalmol       Date:  1986-07

5.  Measurement of optic nerve head pallor with a video-ophthalmograph and with computerized boundary analysis.

Authors:  F S Mikelberg; G R Douglas; S M Drance; M Schulzer; B Schwartz; P Nagin; K Wijsman
Journal:  Can J Ophthalmol       Date:  1988-04       Impact factor: 1.882

6.  Reliability of optic disk topographic measurements recorded with a video-ophthalmograph.

Authors:  F S Mikelberg; G R Douglas; M Schulzer; T N Cornsweet; K Wijsman
Journal:  Am J Ophthalmol       Date:  1984-07-15       Impact factor: 5.258

7.  The reproducibility of computerized boundary analysis for measuring optic disc pallor in the normal optic disc.

Authors:  P Nagin; B Schwartz; K Nanba
Journal:  Ophthalmology       Date:  1985-02       Impact factor: 12.079

  7 in total
  1 in total

1.  Optic disc blood perfusion and oxygenation in glaucoma.

Authors:  Hosni Al Zoubi; Thomas Riemer; Rowena Simon; Walthard Vilser; Somar Hasan; Daniel Meller; Regine Augsten; Martin Hammer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-06-06       Impact factor: 3.535

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.