Literature DB >> 3688099

Reproducibility of topographic measurements with the optic nerve head analyzer.

M B Shields1, J F Martone, A R Shelton, A R Ollie, J MacMillan.   

Abstract

We evaluated the reproducibility of optic nerve head contour mapping by the Optic Nerve Head Analyzer with ten recordings and analyses of one eye each in ten normal volunteers and ten analyses of a single recording in three of the eyes. Reproducibility was good for cup-to-disk ratio and neural rim area. Reproducibility was poor for cup volume, which was inversely related to cup size. Instrument and operator error were low for cup-to-disk ratio and neural rim area, but high for cup volume. Subjective comparisons of contour lines from five recordings of six eyes implied good reproducibility of this measurement.

Entities:  

Mesh:

Year:  1987        PMID: 3688099     DOI: 10.1016/0002-9394(87)90167-x

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  16 in total

1.  Intra- and inter-observer variation of optic nerve head measurements in glaucoma suspects using disc-data.

Authors:  J Stürmer; D Poinoosawmy; D C Broadway; R A Hitchings
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

2.  Early detection of glaucoma by longitudinal monitoring of the optic disc structure.

Authors:  J Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

3.  Topographic changes in the optic disc in eyes with cotton-wool spots and primary open-angle glaucoma.

Authors:  E Chihara; Y Honda
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

4.  Reproducibility of pallor measurements with the optic nerve head analyzer.

Authors:  K N Miller; M B Shields; A R Ollie
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

5.  Correlation between neuroretinal rim area and age in normal subjects.

Authors:  J Funk; T Dieringer; F Grehn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

6.  Quantitative evaluation of optic disc pallor in pseudotumor cerebri patients.

Authors:  S Y Lee; D H Shin; T C Spoor; C S Tsai; C Kim; S H Lee
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

7.  Relationship between optic disc cupping change and intraocular pressure control in adult glaucoma patients.

Authors:  E Z Rath; D H Shin; C Kim; C S Tsai; J H Zeiter; Y J Hong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-07       Impact factor: 3.117

8.  Reproducibility of topographic measures of the glaucomatous optic nerve head.

Authors:  O Geyer; A Michaeli-Cohen; D M Silver; D Versano; M Neudorfer; R Dzhanov; M Lazar
Journal:  Br J Ophthalmol       Date:  1998-01       Impact factor: 4.638

Review 9.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

10.  Limits of two-dimensional planimetry in the follow-up of glaucomatous optic discs.

Authors:  K U Bartz-Schmidt; M Sündtgen; R A Widder; J Weber; G K Krieglstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-05       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.