Federico Caobelli1, James T Thackeray2, Alberto Soffientini3, Frank M Bengel2, Claudio Pizzocaro3, Ugo Paolo Guerra3. 1. Klinik für Nuklearmedizin, Medizinische Hochschule Hannover, Carl Neuberg Strasse, 1, 30625, Hannover, Germany. caobelli.federico@mh-hannover.de. 2. Klinik für Nuklearmedizin, Medizinische Hochschule Hannover, Carl Neuberg Strasse, 1, 30625, Hannover, Germany. 3. Department of Nuclear Medicine, Fondazione Poliambulanza, Brescia, Italy.
Abstract
PURPOSE: IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. METHODS: Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest (99m)Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. RESULTS: Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). CONCLUSION: Image quality and LV functional parameters obtained with a one-eighth acquisition time were statistically comparable to the previously validated one-fourth time protocol using IQ-SPECT. Shorter acquisition times without loss of diagnostic accuracy provide improved patient comfort and streamlined departmental efficiency.
PURPOSE: IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. METHODS: Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest (99m)Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. RESULTS: Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). CONCLUSION: Image quality and LV functional parameters obtained with a one-eighth acquisition time were statistically comparable to the previously validated one-fourth time protocol using IQ-SPECT. Shorter acquisition times without loss of diagnostic accuracy provide improved patient comfort and streamlined departmental efficiency.
Authors: Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian Journal: J Nucl Cardiol Date: 2007 Nov-Dec Impact factor: 5.952
Authors: Martin Havel; Michal Kolacek; Milan Kaminek; Vladimir Dedek; Otakar Kraft; Pavel Sirucek Journal: Hell J Nucl Med Date: 2014 Sep-Dec Impact factor: 1.102
Authors: Federico Caobelli; Stefano Ren Kaiser; James T Thackeray; Frank M Bengel; Matteo Chieregato; Alberto Soffientini; Claudio Pizzocaro; Giordano Savelli; Marco Galelli; Ugo Paolo Guerra Journal: J Nucl Med Date: 2014-11-20 Impact factor: 10.057
Authors: Assuero Giorgetti; Massimiliano Rossi; Mario Stanislao; Guido Valle; Pietro Bertolaccini; Alberto Maneschi; Raffaele Giubbini; Maria Luisa De Rimini; Marco Mazzanti; Mario Cappagli; Elisa Milan; Duccio Volterrani; Paolo Marzullo Journal: J Nucl Med Date: 2007-09-14 Impact factor: 10.057
Authors: Mansour M Alqahtani; Kathy P Willowson; Chris Constable; Roger Fulton; Peter L Kench Journal: J Appl Clin Med Phys Date: 2022-01-20 Impact factor: 2.102