Literature DB >> 25526755

Myocardial perfusion imaging parameters: IQ-SPECT and conventional SPET system comparison.

Martin Havel1, Michal Kolacek, Milan Kaminek, Vladimir Dedek, Otakar Kraft, Pavel Sirucek.   

Abstract

Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solutions, USA) and conventional single photon emission tomography (SPET) system equipped with standard low energy high resolution collimators. A group of randomly selected 81 patients underwent consecutively the MPI procedure on IQ-SPECT and on conventional SPET systen, both without attenuation correction. The summed scores and the values of the functional parameters of the left ventricle: ejection fraction (EF), end-systolic and end-diastolic volumes (ESV, EDV) received from the automatic analysis software were compared and statistically analyzed. Our results showed that summed scores values were significantly higher for the IQ-SPECT system in comparison to the conventional one. Calculated EF were significantly lower for IQ-SPECT, whereas evaluated left ventricular volumes (LVV) were significantly higher for this system. In conclusion, we recorded significant differences in automatically calculated semiquantitative perfusion and functional parameters when compared uncorrected studies obtained by the IQ-SPECT with the conventional SPET system.

Entities:  

Mesh:

Year:  2014        PMID: 25526755

Source DB:  PubMed          Journal:  Hell J Nucl Med        ISSN: 1790-5427            Impact factor:   1.102


  5 in total

1.  Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.

Authors:  Koichi Okuda; Kenichi Nakajima; Shinro Matsuo; Chisato Kondo; Masayoshi Sarai; Yoriko Horiguchi; Takahiro Konishi; Masahisa Onoguchi; Takeshi Shimizu; Seigo Kinuya
Journal:  J Nucl Cardiol       Date:  2017-01-03       Impact factor: 5.952

2.  Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT.

Authors:  Federico Caobelli; James T Thackeray; Alberto Soffientini; Frank M Bengel; Claudio Pizzocaro; Ugo Paolo Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-01       Impact factor: 9.236

3.  Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

Authors:  Ian S Armstrong; Kimberley J Saint; Christine M Tonge; Parthiban Arumugam
Journal:  J Nucl Cardiol       Date:  2016-01-25       Impact factor: 5.952

4.  Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation.

Authors:  Morgan C Lyon; Courtney Foster; Xinhong Ding; Sharmila Dorbala; Don Spence; Manojeet Bhattacharya; A Hans Vija; Marcelo F DiCarli; Stephen C Moore
Journal:  J Nucl Cardiol       Date:  2016-03-31       Impact factor: 5.952

5.  Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

Authors:  Eero Hippeläinen; Teemu Mäkelä; Touko Kaasalainen; Erna Kaleva
Journal:  EJNMMI Phys       Date:  2017-07-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.