Literature DB >> 26206767

A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy.

Saber Nankali1, Ahmad Esmaili Torshabi1, Payam Samadi Miandoab1.   

Abstract

At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor position while the contrast of implanted clip is highly observable rather than tumor. As alternative, using natural anatomical landmarks located at thorax region of patient body is proposed to extract tumor position information without implanting clips that is invasive method with possible side effect. Among natural landmarks, ribs of rib-cage structure that result proper visualization at X-ray images may be optimal as representative for tumor motion. In this study, we investigated the existence of possible correlation between ribs as natural anatomical landmarks and various lung and liver tumors located at different sites as challenging issue. A simulation study was performed using data extracted from 4-dimensional extended cardiac-torso anthropomorphic phantom that is able to simulate motion effect of dynamic organs, as well. Several tumor sites with predefined distances originated from chosen ribs at anterior-posterior direction were simulated at 3 upper, middle, and lower parts of chest. Correlation coefficient between ribs and tumors was calculated to investigate the robustness of ribs as anatomical landmarks for tumor motion tracking. Moreover, a consistent correlation model was taken into account to track tumor motion with a rib as best candidate among selected ribs. Final results represent availability of using rib cage as anatomical landmark to track lung and liver tumors in a noninvasive way. Observations of our calculations showed a proper correlation between tumors and ribs while the degree of this correlation is changing depends on tumor site while lung tumors are more varied and complex with less correlation with ribs motion against liver tumors.

Entities:  

Keywords:  anatomical landmarks; external beam radiotherapy; rib cage; tumor motion tracking

Mesh:

Substances:

Year:  2016        PMID: 26206767      PMCID: PMC5616108          DOI: 10.1177/1533034615595737

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  41 in total

1.  Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field.

Authors:  C Kirkby; B Murray; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Feasibility of using ultrasound for real-time tracking during radiotherapy.

Authors:  A Hsu; N R Miller; P M Evans; J C Bamber; S Webb
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

3.  The correlation evaluation of a tumor tracking system using multiple external markers.

Authors:  Hui Yan; Fang-Fang Yin; Guo-Pei Zhu; Munther Ajlouni; Jae Ho Kim
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

5.  Respiration gated radiotherapy treatment: a technical study.

Authors:  H D Kubo; B C Hill
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

6.  Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

Authors:  Ross McGurk; Joao Seco; Marco Riboldi; John Wolfgang; Paul Segars; Harald Paganetti
Journal:  Phys Med Biol       Date:  2010-02-16       Impact factor: 3.609

7.  Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancer.

Authors:  Simon Hughes; James McClelland; Segolene Tarte; David Lawrence; Shahreen Ahmad; David Hawkes; David Landau
Journal:  Radiother Oncol       Date:  2009-04-22       Impact factor: 6.280

8.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

9.  Reproducibility of the abdominal and chest wall position by voluntary breath-hold technique using a laser-based monitoring and visual feedback system.

Authors:  Katsumasa Nakamura; Yoshiyuki Shioyama; Satoru Nomoto; Saiji Ohga; Takashi Toba; Tadamasa Yoshitake; Shigeo Anai; Hiromi Terashima; Hiroshi Honda
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-05-01       Impact factor: 7.038

10.  An adaptive fuzzy prediction model for real time tumor tracking in radiotherapy via external surrogates.

Authors:  Ahmad Esmaili Torshabi; Marco Riboldi; Abbas Ali Imani Fooladi; Seyed Mehdi Modarres Mosalla; Guido Baroni
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

View more
  2 in total

1.  Biomechanical Morphing for Personalized Fitting of Scoliotic Torso Skeleton Models.

Authors:  Christos Koutras; Hamed Shayestehpour; Jesús Pérez; Christian Wong; John Rasmussen; Maxime Tournier; Matthieu Nesme; Miguel A Otaduy
Journal:  Front Bioeng Biotechnol       Date:  2022-07-19

2.  Investigation of tumor and vessel motion correlation in the liver.

Authors:  Sydney A Jupitz; Andrew J Shepard; Patrick M Hill; Bryan P Bednarz
Journal:  J Appl Clin Med Phys       Date:  2020-06-13       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.