Literature DB >> 16013706

Feasibility of using ultrasound for real-time tracking during radiotherapy.

A Hsu1, N R Miller, P M Evans, J C Bamber, S Webb.   

Abstract

This study was designed to examine the feasibility of utilizing transabdominal ultrasound for real-time monitoring of target motion during a radiotherapy fraction. A clinical Acuson 128/XP ultrasound scanner was used to image various stationary and moving phantoms while an Elekta SL25 linear accelerator radiotherapy treatment machine was operating. The ultrasound transducer was positioned to image from the outer edge of the treatment field at all times. Images were acquired to videotape and analyzed using in-house motion tracking algorithms to determine the effect of the SL25 on the quality of the displacement measurements. To determine the effect on the dosimetry of the presence of the transducer, dose distributions were examined using thermoluminescent dosimeters loaded into an Alderson Rando phantom and exposed to a 10 x 10 cm2 treatment field with and without the ultrasound transducer mounted 2.5 cm outside the field edge. The ultrasound images acquired a periodic noise that was shown to occur at the pulsing frequency of the treatment machine. Images of moving tissue were analyzed and the standard deviation on the displacement estimates within the tissue was identical with the SL25 on and off. This implies that the periodic noise did not significantly degrade the precision of the tracking algorithm (which was better than 0.01 mm). The presence of the transducer at the surface of the phantom presented only a 2.6% change to the dose distribution to the volume of the phantom. The feasibility of ultrasonic motion tracking during radiotherapy treatment is demonstrated. This presents the possibility of developing a noninvasive, real-time and low-cost method of tracking target motion during a treatment fraction.

Mesh:

Year:  2005        PMID: 16013706     DOI: 10.1118/1.1915934

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

Authors:  Manju Sharma; Troy Dos Santos; Nikolaos P Papanikolopoulos; Susanta Kumar Hui
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  [Image-guided radiation therapy].

Authors:  J Boda-Heggemann; M Guckenberger; U Ganswindt; C Belka; H Wertz; M Blessing; F Wenz; M Fuss; F Lohr
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  [Ultrasound motion tracking for radiation therapy].

Authors:  J Jenne; J Schwaab
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

4.  Monte Carlo modeling of ultrasound probes for image guided radiotherapy.

Authors:  Magdalena Bazalova-Carter; Jeffrey Schlosser; Josephine Chen; Dimitre Hristov
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

5.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

6.  A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy.

Authors:  Saber Nankali; Ahmad Esmaili Torshabi; Payam Samadi Miandoab
Journal:  Technol Cancer Res Treat       Date:  2016-07-09

7.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

8.  A block matching based approach with multiple simultaneous templates for the real-time 2D ultrasound tracking of liver vessels.

Authors:  Andrew J Shepard; Bo Wang; Thomas K F Foo; Bryan P Bednarz
Journal:  Med Phys       Date:  2017-10-13       Impact factor: 4.071

9.  3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.

Authors:  Charles K Matrosic; Wesley Culberson; Andrew Shepard; Sydney Jupitz; Bryan Bednarz
Journal:  Phys Med       Date:  2021-04-23       Impact factor: 2.685

10.  Hypofractionated image-guided breath-hold SABR (stereotactic ablative body radiotherapy) of liver metastases--clinical results.

Authors:  Judit Boda-Heggemann; Dietmar Dinter; Christel Weiss; Anian Frauenfeld; Kerstin Siebenlist; Ulrike Attenberger; Martine Ottstadt; Frank Schneider; Ralf-Dieter Hofheinz; Frederik Wenz; Frank Lohr
Journal:  Radiat Oncol       Date:  2012-06-18       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.