Feasibility of common carotid artery point of care ultrasound in cardiac output measurements compared to invasive methods.

Marika Gassner1, Keith Killu1, Zachary Bauman1, Victor Coba1, Kelly Rosso1, Dionne Blyden1.   

Abstract

BACKGROUND: Cardiac output (CO) measurement in the intensive care unit (ICU) requires invasive devices such as the pulmonary artery (PA) catheter or arterial waveform pulse contour analysis (PCA). This study tests the accuracy and feasibility of point of care ultrasound (POCUS) of the common carotid artery to estimate the CO non-invasively and compare it to existing invasive CO measurement modalities.
METHODS: Patients admitted to the surgical and cardiothoracic ICU in a tertiary university-affiliated academic center during a 4-month period, with invasive hemodynamic monitoring devices for management, were included in this cohort study. Common carotid artery POCUS was performed to measure the CO and the results were compared to an invasive device.
RESULTS: Intensivists and ICU fellows, using ultrasound of the common carotid artery, obtained the CO measurements. Images of the Doppler flow and volume were obtained at the level of the thyroid gland. Concurrent CO measured via invasive devices was recorded. The patient cohort comprised 36 patients; 52 % were females. The average age was 59 ± 13 years, and 66 % were monitored via PCA device and 33 % via PA catheter. Intraclass correlation coefficient (ICC) analysis demonstrated almost perfect correlation (0.8152) between measurements of CO via ultrasound vs. invasive modalities. The ICC between POCUS and the invasive measurement via PCA was 0.84 and via PA catheter 0.74, showing substantial agreement between the ultrasound and both invasive modalities.
CONCLUSIONS: Common carotid artery POCUS offers a non-invasive method of measuring the CO in the critically ill population.

Entities:  

Keywords:  Cardiac output; Carotid doppler; Point of care ultrasound; Pulmonary artery catheter; Pulse contour analysis; Ultrasound

Year:  2014        PMID: 26191100      PMCID: PMC4504859          DOI: 10.1007/s40477-014-0139-9

Source DB:  PubMed          Journal:  J Ultrasound        ISSN: 1876-7931


  15 in total

Review 1.  Complications of central venous catheters: internal jugular versus subclavian access--a systematic review.

Authors:  Sibylle Ruesch; Bernhard Walder; Martin R Tramèr
Journal:  Crit Care Med       Date:  2002-02       Impact factor: 7.598

2.  Lack of association between carotid artery volume blood flow and cardiac output.

Authors:  B M Eicke; J von Schlichting; S Mohr-Ahaly; A Schlosser; R S von Bardeleben; F Krummenauer; H C Hopf
Journal:  J Ultrasound Med       Date:  2001-12       Impact factor: 2.153

Review 3.  Preventing complications of central venous catheterization.

Authors:  David C McGee; Michael K Gould
Journal:  N Engl J Med       Date:  2003-03-20       Impact factor: 91.245

4.  Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output.

Authors:  A K Sinha; C Cane; S T Kempley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-01       Impact factor: 5.747

5.  The distribution of blood flow in the carotid and vertebral arteries during dynamic exercise in humans.

Authors:  Kohei Sato; Shigehiko Ogoh; Ai Hirasawa; Anna Oue; Tomoko Sadamoto
Journal:  J Physiol       Date:  2011-03-28       Impact factor: 5.182

6.  Loss of cerebral regulation during cardiac output variations in focal cerebral ischemia.

Authors:  B I Tranmer; T S Keller; G W Kindt; D Archer
Journal:  J Neurosurg       Date:  1992-08       Impact factor: 5.115

7.  Modification of focal cerebral ischemia by cardiac output augmentation.

Authors:  T S Keller; J E McGillicuddy; V A LaBond; G W Kindt
Journal:  J Surg Res       Date:  1985-11       Impact factor: 2.192

8.  Effect of lower limb compression devices on thermodilution cardiac output measurement.

Authors:  Keith Killu; John M Oropello; Anthony R Manasia; Roopa Kohli-Seth; Adel Bassily-Marcus; Andrew Leibowitz; Rosanna DelGiudice; Victor Murgolo; Ernest Benjamin
Journal:  Crit Care Med       Date:  2007-05       Impact factor: 7.598

9.  Understanding changes in established practice: pulmonary artery catheter use in critically ill patients.

Authors:  Hayley B Gershengorn; Hannah Wunsch
Journal:  Crit Care Med       Date:  2013-12       Impact factor: 7.598

Review 10.  Pulmonary artery catheters for adult patients in intensive care.

Authors:  Sujanthy S Rajaram; Nayan K Desai; Ankur Kalra; Mithil Gajera; Susan K Cavanaugh; William Brampton; Duncan Young; Sheila Harvey; Kathy Rowan
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28
View more
  11 in total

1.  Volumetric blood flow measurement using Doppler ultrasound: concerns about the technique.

Authors:  Pablo Blanco
Journal:  J Ultrasound       Date:  2015-03-18

2.  Evidence for non-Newtonian behavior of intracranial blood flow from Doppler ultrasonography measurements.

Authors:  Khalid M Saqr; Ossama Mansour; Simon Tupin; Tamer Hassan; Makoto Ohta
Journal:  Med Biol Eng Comput       Date:  2018-12-07       Impact factor: 2.602

3.  Carotid Doppler Ultrasonography for Hemodynamic Assessment in Critically Ill Children.

Authors:  Aline Junqueira Rubio; Luiza Lobo de Souza; Roberto J N Nogueira; Marcelo B Brandão; Tiago H de Souza
Journal:  Pediatr Cardiol       Date:  2021-09-13       Impact factor: 1.655

4.  Comparison of cardiac output measured by carotid artery Doppler ultrasound and echocardiography in patients admitted to Golestan and Imam Khomeyni Hospitalsl in Ahvaz.

Authors:  Zahra Fazelinejad; Mohammad Ghasem Hanafi; Forough Amiripebdani; Aslan Mosavi
Journal:  J Family Med Prim Care       Date:  2020-07-30

5.  A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: A pilot study.

Authors:  Jon-Émile S Kenny; Igor Barjaktarevic; Andrew M Eibl; Matthew Parrotta; Bradley F Long; Joseph K Eibl
Journal:  Health Sci Rep       Date:  2020-10-05

6.  The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

Authors:  Tom Peachey; Andrew Tang; Elinor C Baker; Jason Pott; Yonathan Freund; Tim Harris
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-02       Impact factor: 2.953

7.  Carotid and femoral Doppler do not allow the assessment of passive leg raising effects.

Authors:  Valentina Girotto; Jean-Louis Teboul; Alexandra Beurton; Laura Galarza; Thierry Guedj; Christian Richard; Xavier Monnet
Journal:  Ann Intensive Care       Date:  2018-05-29       Impact factor: 6.925

8.  Sex differences for fatigue-induced changes in muscle blood flow, but not eccentric peak torque or neuromuscular responses.

Authors:  Ethan C Hill; Terry J Housh; Joshua L Keller; Cory M Smith; Richard J Schmidt; Glen O Johnson
Journal:  J Musculoskelet Neuronal Interact       Date:  2018-12-01       Impact factor: 2.041

9.  The Contributions of Arterial Cross-Sectional Area and Time-Averaged Flow Velocity to Arterial Blood Flow.

Authors:  Ethan C Hill; Terry J Housh; Cory M Smith; Joshua L Keller; Richard J Schmidt; Glen O Johnson
Journal:  J Med Ultrasound       Date:  2018-07-05

10.  Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.

Authors:  Yun Zhang; Yan Wang; Jing Shi; Zhiqiang Hua; Jinyu Xu
Journal:  PLoS One       Date:  2019-10-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.