Ethan C Hill1, Terry J Housh, Joshua L Keller, Cory M Smith, Richard J Schmidt, Glen O Johnson.
Abstract
OBJECTIVES: The purpose of this study was to examine the effects of exercise intensity and strength on sex-related differences in eccentric peak torque (PT), muscle blood flow, and neuromuscular responses following fatiguing, submaximal forearm flexion eccentric protocols.Entities:
Mesh:
Year: 2018 PMID: 30511947 PMCID: PMC6313047
Source DB: PubMed Journal: J Musculoskelet Neuronal Interact ISSN: 1108-7161 Impact factor: 2.041
Group stratification of the men and women by pretest eccentric peak torque. Each group of men and women was divided equally into 2 groups of strong men (or strong women) and less strong men (or less strong women Thus, 4 groups (strong men, less strong men, strong women, and less strong women) of nine were created, stratified by muscle strength according to their pretest eccentric peak torque values.
| Eccentric Peak Torque (Nm) | ||||
|---|---|---|---|---|
| Group | 40% Protocol | 80% Protocol | ||
| Mean | Range | Mean | Range | |
| Less Strong Women | 35.0 ± 3.8 | 28.1 - 40.2 | 33.4 ± 4.8 | 25.9 - 39.3 |
| Strong Women | 46.3 ± 3.5 | 41.6 - 51.1 | 46.3 ± 3.2 | 40.5 - 50.0 |
| Less Strong Men | 65.4 ± 6.9 | 56.7 - 76.0 | 63.5 ± 6.6 | 55.0 - 75.4 |
| Strong Men | 81.5 ± 6.0 | 77.3 - 91.0 | 80.3 ± 8.0 | 76.8 - 90.2 |
The intraclass correlation coefficient (ICC), standard error of the measurement (SEM), percent of grand mean, and mean (± SD) of visits 1 and 2 for all measured variables from the combined sample (n=36) of men (n=18) and women (n=18).
| Variables | ICC | SEM | % Grand Mean | Mean Visit 1 | Mean Visit 2 |
|---|---|---|---|---|---|
| Eccentric PT (Nm) | 0.961 | 5.42 | 9.7% | 56.79 ± 20.19 | 54.52 ± 17.90 |
| Arterial Cross-Sectional Area | 0.957 | 0.011 | 9.9% | 0.111 ± 0.036 | 0.111 ± 0.043 |
| Time Averaged Flow Velocity (cm·s-1) | 0.827 | 4.06 | 19.1% | 21.24 ± 7.14 | 21.31 ± 7.67 |
| Muscle Blood Flow (mL·min-1) | 0.888 | 31.35 | 21.8% | 142.07 ± 65.7 | 145.16 ± 72.37 |
| Eccentric PT EMG Amplitude (µV) | 0.751 | 192.11 | 15.8% | 1186.3 ± 446.7 | 1240.7 ± 670.7 |
| Eccentric PT EMG Mean Power Frequency (Hz) | 0.671 | 7.86 | 12.2% | 65.54 ± 8.47 | 63.70 ± 10.47 |
| Eccentric PT MMG Amplitude (m·s-2) | 0.584 | 0.115 | 15.9% | 0.738 ± 0.475 | 0.706 ± 0.331 |
| Eccentric PT MMG Mean Power Frequency (Hz) | 0.412 | 5.54 | 17.2% | 31.85 ± 6.98 | 32.65 ± 8.67 |
There were no significant (p > 0.05) mean differences for visit 1 versus visit 2 for any of the variables. All measurements were performed at baseline prior to the fatiguing protocol.
Figure 1The individual (empty circles) and mean (solid horizontal lines) eccentric peak torque (PT) responses (collapsed across the 40% and 80% protocols) at pretest, posttest, and 5-min recovery for the less strong women, strong women, less strong men, and strong men. For all groups, eccentric PT decreased from pretest to posttest and for all groups, eccentric PT partially returned to pretest levels at 5-min recovery.
Figure 2The mean (± SE) muscle blood flow responses (collapsed across the 40% and 80% protocols) at baseline, posttest, and 5-min recovery for the less strong women (circles with dotted line), strong women (squares with solid line), less strong men (triangles with dotted line), and strong men (diamonds with solid line). There were significant increases in muscle blood flow from pretest to posttest for all groups. At 5-min recovery, muscle blood flow partially returned to pretest levels for both groups of women, but remained elevated for both groups of men.
Pretest, posttest, and 5-min recovery normalized (to maximal isometric electromyographic (EMG) amplitude, EMG mean power frequency, mechanomyographic (MMG) amplitude, and MMG mean power frequency) neuromuscular responses (collapsed across Group and Intensity) during the eccentric peak torque (PT) muscle actions as a result of the fatiguing protocols.
| Variables | Pretest | Posttest | 5-min Recovery |
|---|---|---|---|
| Eccentric PT EMG Amplitude | 0.957 ± 0.027 | 0.843 ± 0.029 | 0.852 ± 0.024 |
| Eccentric PT EMG Mean Power Frequency | 0.999 ± 0.021 | 0.985 ± 0.018 | 1.066 ± 0.021 |
| Eccentric PT MMG Amplitude | 1.811 ± 0.139 | 1.700 ± 0.104 | 1.902 ± 0.246 |
| Eccentric PT MMG Mean Power Frequency | 1.178 ± 0.035 | 1.116 ± 0.059 | 1.151 ± 0.060 |
Values are collapsed across Group and Intensity because there were no significant (p<0.05) Group or Intensity effects.
Significant (p<0.05) greater than pretest (main effect for Time).
Significant (p<0.05) less than pretest (main effect for Time).