Literature DB >> 11762541

Lack of association between carotid artery volume blood flow and cardiac output.

B M Eicke1, J von Schlichting, S Mohr-Ahaly, A Schlosser, R S von Bardeleben, F Krummenauer, H C Hopf.   

Abstract

OBJECTIVE: The correlation of cardiac output and cerebral perfusion is unclear. We tested this potential association by correlating cardiac output data obtained by echocardiography and cerebral blood flow data as determined by color M-mode measurements of carotid artery blood flow.
METHODS: We studied 43 patients with a broad spectrum of cardiac performance by means of transthoracic echocardiography. In these patients, different cardiac indices such as stroke volume, ejection fraction, and heart minute volume were determined. The data were correlated with volumetric flow measurements (color M-mode duplex system) of the common carotid arteries bilaterally.
RESULTS: Heart minute volume ranged from 1.632 to 9.836 mL/min (mean +/- SD, 4.652 +/- 1.621 mL/min); ejection fraction ranged from 18% to 76% (mean, 48% +/- 16%). The relative fraction of carotid volume flow compared with heart minute volume was 15% +/- 6%. There was no correlation between ejection fraction, stroke volume, or heart minute volume and absolute volume flow in the carotid arteries when being adjusted for age. There was a highly significant inverse correlation (r = -0.8; P < .0001) of the relative fraction of the carotid volume flow (carotid volume flow/heart minute volume [percent]) and the heart minute volume.
CONCLUSION: Our data support the concept that cerebral blood flow is independent of cardiac output.

Entities:  

Mesh:

Year:  2001        PMID: 11762541     DOI: 10.7863/jum.2001.20.12.1293

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  6 in total

1.  Transcatheter aortic valve implantation improves carotid and vertebral arterial blood flow in patients with severe aortic stenosis: practical role of orthostatic stress test.

Authors:  Pawel Kleczyński; Pawel Petkow Dimitrow; Artur Dziewierz; Andrzej Surdacki; Dariusz Dudek
Journal:  Clin Cardiol       Date:  2017-03-08       Impact factor: 2.882

2.  The relationship between cardiac output and dynamic cerebral autoregulation in humans.

Authors:  B M Deegan; E R Devine; M C Geraghty; E Jones; G Ólaighin; J M Serrador
Journal:  J Appl Physiol (1985)       Date:  2010-08-05

3.  Feasibility of common carotid artery point of care ultrasound in cardiac output measurements compared to invasive methods.

Authors:  Marika Gassner; Keith Killu; Zachary Bauman; Victor Coba; Kelly Rosso; Dionne Blyden
Journal:  J Ultrasound       Date:  2014-11-12

4.  Carotid and femoral Doppler do not allow the assessment of passive leg raising effects.

Authors:  Valentina Girotto; Jean-Louis Teboul; Alexandra Beurton; Laura Galarza; Thierry Guedj; Christian Richard; Xavier Monnet
Journal:  Ann Intensive Care       Date:  2018-05-29       Impact factor: 6.925

5.  Cerebral blood flow alteration following acute myocardial infarction in mice.

Authors:  Abdullah Kaplan; Andriy Yabluchanskiy; Rana Ghali; Raffaele Altara; George W Booz; Fouad A Zouein
Journal:  Biosci Rep       Date:  2018-09-05       Impact factor: 3.840

6.  A Carotid Doppler Patch Accurately Tracks Stroke Volume Changes During a Preload-Modifying Maneuver in Healthy Volunteers.

Authors:  Jon-Émile S Kenny; Igor Barjaktarevic; Andrew M Eibl; Matthew Parrotta; Bradley F Long; Joseph K Eibl; Frederic Michard
Journal:  Crit Care Explor       Date:  2020-01-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.