Literature DB >> 26174969

Intra-session repeatability of iridocorneal angle measurements provided by a Scheimpflug photography-based system in healthy eyes.

Clara Ruiz-Belda1,2, David P Piñero3,4,5, Pedro Ruiz-Fortes1,2, Roberto Soto-Negro1,2, Myriam Moya6, Rafael J Pérez-Cambrodí1,2, Alberto Artola1,7.   

Abstract

PURPOSE: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode.
METHODS: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system. Three consecutive measurements of nasal and temporal angles at 0°, ±10°, ±20°, and ±30° meridians were obtained in order to assess the intra-session repeatability of iridocorneal angle measurements provided by the device using the glaucoma analysis mode. Within-subject standard deviation (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) values were calculated.
RESULTS: The mean Sw was 1.07 ± 1.09°, 1.22 ± 1.53°, 0.66 ± 0.51°, 0.86 ± 0.57°, 0.68 ± 0.65°, 0.84 ± 0.68°, and 0.91 ± 0.70° at the temporal 30°, 20°, 10°, 0°, -10°, -20°, and -30° positions, respectively. Mean Sw was 3.13 ± 3.15°, 3.43 ± 3.63°, 2.75 ± 2.29°, 2.19 ± 1.55°, 1.90 ± 1.49°, 2.14 ± 1.74°, and 2.24 ± 2.06° at the temporal -30°, -20°, -10°, 0°, 10°, 20°, and 30° positions, respectively. Mean CV ranged from 1.36 ± 1.05 % (nasal 0° position) to 10.92 ± 13.95 % (nasal -20° position). ICC values ranged from 0.778 to 0.972.
CONCLUSIONS: The glaucoma analysis mode of the Sirius system provides consistent measurements of the iridocorneal angle at different meridians in healthy eyes, with slightly less consistency for nasal measurements. It may be considered a clinically useful non-invasive technique for the detection of potentially occludable angles.

Entities:  

Keywords:  Anterior chamber angle; Iridocorneal angle; Scheimpflug imaging; Sirius

Mesh:

Year:  2015        PMID: 26174969     DOI: 10.1007/s00417-015-3105-0

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  23 in total

1.  Aging of the human lens: changes in lens shape at zero-diopter accommodation.

Authors:  J F Koretz; C A Cook; P L Kaufman
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2001-02       Impact factor: 2.129

2.  Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth.

Authors:  Andrea Bedei; Ilaria Appolloni; Antonio Madesani; Alessia Pietrelli; Sara Franceschi; Lucio Barabesi
Journal:  Eur J Ophthalmol       Date:  2012       Impact factor: 2.597

3.  Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study.

Authors:  Liang Xu; Wei Fang Cao; Ya Xing Wang; Chang Xi Chen; Jost B Jonas
Journal:  Am J Ophthalmol       Date:  2008-03-12       Impact factor: 5.258

Review 4.  Technologies for anatomical and geometric characterization of the corneal structure and anterior segment: a review.

Authors:  David P Piñero
Journal:  Semin Ophthalmol       Date:  2013-10-31       Impact factor: 1.975

5.  Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study.

Authors:  Tin A Tun; Mani Baskaran; Shamira A Perera; Anita S Chan; Ching-Yu Cheng; Hla M Htoon; Lisandro M Sakata; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-30       Impact factor: 3.117

6.  A proposed simple method for measurement in the anterior chamber angle: biometric gonioscopy.

Authors:  N G Congdon; G L Spaeth; J Augsburger; J Klancnik; K Patel; D G Hunter
Journal:  Ophthalmology       Date:  1999-11       Impact factor: 12.079

7.  Evaluation of anterior segment parameter changes using the Pentacam after uneventful phacoemulsification.

Authors:  Selim Doganay; Penpegul Bozgul Firat; Sinan Emre; Saim Yologlu
Journal:  Acta Ophthalmol       Date:  2008-12-02       Impact factor: 3.761

8.  Repeatability, reproducibility, and agreement between three different Scheimpflug systems in measuring corneal and anterior segment biometry.

Authors:  Julio C Hernández-Camarena; Patricia Chirinos-Saldaña; Alejandro Navas; Arturo Ramirez-Miranda; Angle de la Mota; Aida Jimenez-Corona; Enrique O Graue-Hernindez
Journal:  J Refract Surg       Date:  2014-09       Impact factor: 3.573

9.  Repeatability of ocular measurements with a dual-Scheimpflug analyzer in healthy eyes.

Authors:  Carmen Lopez de la Fuente; Ana Sanchez-Cano; Francisco Segura; Lorena Fuentes-Broto; Isabel Pinilla
Journal:  Biomed Res Int       Date:  2014-04-24       Impact factor: 3.411

10.  Morphological analysis of age-related iridocorneal angle changes in normal and glaucomatous cases using anterior segment optical coherence tomography.

Authors:  Yuko Maruyama; Kazuhiko Mori; Yoko Ikeda; Morio Ueno; Shigeru Kinoshita
Journal:  Clin Ophthalmol       Date:  2013-12-21
View more
  4 in total

Review 1.  Anterior Chamber Angle Assessment Techniques: A Review.

Authors:  Ivano Riva; Eleonora Micheletti; Francesco Oddone; Carlo Bruttini; Silvia Montescani; Giovanni De Angelis; Luigi Rovati; Robert N Weinreb; Luciano Quaranta
Journal:  J Clin Med       Date:  2020-11-25       Impact factor: 4.241

2.  Intra-session repeatability of iridocorneal angle measurements in normal subjects and glaucoma patients using Scheimpflug-Placido disc topographer.

Authors:  Tarannum Mansoori; Nagalla Balakrishna
Journal:  Indian J Ophthalmol       Date:  2022-05       Impact factor: 2.969

3.  Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

Authors:  Aysun Şanal Doğan; Canan Gürdal; Mehmet Talay Köylü
Journal:  Turk J Ophthalmol       Date:  2018-04-25

4.  Anterior Chamber Angle and Volume Do Not Change after Myopic Laser-Assisted In Situ Keratomileusis in Young Patients.

Authors:  Ertuğrul Tan Yassa; Cihan Ünlü
Journal:  J Ophthalmol       Date:  2018-12-10       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.