In vitro evaluation of the implant abutment connection sealing capability of different implant systems.

P G Coelho1, P Sudack, M Suzuki, K S Kurtz, G E Romanos, N R F A Silva.   

Abstract

This study sought to evaluate the sealing capability of the implant abutment connection of different dental implant systems. Five Nobel Replace select, Straumann and Intra-lock implants of approximately 4.5 mm diameter with their respective abutments were provided by the manufacturers. A calibration curve was determined by placing toluidine blue (TB) increments of 0.1 microL into 1.5 mL of distilled water and recording its absorbance in a spectrophotometer until reaching 0.7 microL. Then, 0.7 microL of TB was placed in the deepest portion of each implant's internal screw, the abutments were adapted to the implant according to the manufacturer's instructions and the specimens were placed in vials with 1.5 mL of distilled water. Spectrophotometric analysis was performed at 1, 3, 6, 24, 48, 72, 96 and 144 h. Statistical analysis was performed by One-way anova at 95% level of significance. The calibration curve was linear with respect to the TB amount in 1.5 microL distilled water (R(2) = 0.9961). All implant abutment systems presented an increase in absorbance as a function of time. As time elapsed in vitro, significantly higher amounts of TB was released from the Straumann and Nobel Replace Select connection systems (P < 0.0001). Leakage was significant between the groups. Despite controlled torquing, the seal between the implant body and the abutment could not be maintained in all three of the systems tested.

Entities:  

Mesh:

Year:  2008        PMID: 18976264     DOI: 10.1111/j.1365-2842.2008.01886.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  17 in total

1.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

2.  Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Authors:  Sönke Harder; Birka Dimaczek; Yaha Açil; Hendrik Terheyden; Sandra Freitag-Wolf; Matthias Kern
Journal:  Clin Oral Investig       Date:  2009-07-23       Impact factor: 3.573

3.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

4.  Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

Authors:  D Martin-Gili; M Molmeneu; M Fernandez; M Punset; Ll Giner; J Armengou; F Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2015-07-15       Impact factor: 3.896

5.  In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.

Authors:  Deceles Cristina Costa Alves; Paulo Sérgio Perri de Carvalho; Carlos Nelson Elias; Eduardo Vedovatto; Elizabeth Ferreira Martinez
Journal:  Clin Oral Investig       Date:  2016-02-20       Impact factor: 3.573

6.  Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent.

Authors:  Pedro Ferrás Fernandes; Liliana Grenho; Maria Helena Fernandes; João Carlos Sampaio-Fernandes; Pedro Sousa Gomes
Journal:  Odontology       Date:  2021-08-27       Impact factor: 2.634

7.  Analysis of the intraimplant microflora of two-piece dental implants.

Authors:  Sönke Harder; Rainer Podschun; Livia Grancicova; Christian Mehl; Matthias Kern
Journal:  Clin Oral Investig       Date:  2012-09-08       Impact factor: 3.573

8.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

9.  Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment.

Authors:  Jacques-Henri Torres; Michael Mechali; Olivier Romieu; Paul Tramini; Sylvie Callas; Frédéric Jg Cuisinier; Bernard Levallois
Journal:  Biomed Eng Online       Date:  2011-04-14       Impact factor: 2.819

10.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.