Literature DB >> 16104954

Bone reactions to longstanding functional load at implants: an experimental study in dogs.

T Berglundh1, I Abrahamsson, J Lindhe.   

Abstract

OBJECTIVES: The aims of the present investigation were (i) to study marginal bone level alterations following implant installation, abutment connection and functional loading and (ii) to analyse bone tissue reactions to functional load.
MATERIAL AND METHODS: Six beagle dogs, about 1-year old, were used. All mandibular pre-molars were extracted. Three months later four implants of the Astra Tech Implants Dental System were installed in one side of the mandible and four standard fixtures of the Brånemark System were placed in the contralateral side of the mandible. Abutment connection was performed 3 months later and a plaque control programme was initiated. Three months after abutment connection fixed partial dentures (FPDs) made in gold were cemented to the maxillary canines and pre-molars. FPDs were also connected to the three posterior implants in each side of the mandible, while the mesial implant in each side was used as an unloaded control. Radiographs were obtained from all implant sites following implant installation, abutment connection and FPD placement. Ten months after the FPD placement the radiographic examination was repeated. The animals were sacrificed and biopsies from all implant sites were obtained and prepared for histological analysis.
RESULTS: The radiographic analysis revealed that largest amount of bone loss occurred following implant installation and abutment connection and that this loss was more pronounced at Brånemark than at Astra implants. The bone level alterations that were observed at implants exposed to 10 months of functional load in both implant systems were small and did not differ from control sites. The histological analysis revealed that implants exposed to functional load exhibited a higher degree of bone-to-implant contact than control implants in both implant systems.
CONCLUSION: It is suggested that functional load at implants may enhance osseointegration and does not result in marginal bone loss.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16104954     DOI: 10.1111/j.1600-051X.2005.00747.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  13 in total

1.  Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

Authors:  D Martin-Gili; M Molmeneu; M Fernandez; M Punset; Ll Giner; J Armengou; F Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2015-07-15       Impact factor: 3.896

2.  Clinical assessment of submerged vs non-submerged implants placed in pristine bone.

Authors:  P Cardelli; F Cecchetti; M Montani; E Bramanti; C Arcuri
Journal:  Oral Implantol (Rome)       Date:  2014-05-19

3.  Immediate Implant Placement in Infected Sockets: A Consecutive Cohort Study.

Authors:  Ashish Kakar; Kanupriya Kakar; Minas D Leventis; Gaurav Jain
Journal:  J Lasers Med Sci       Date:  2020-03-15

4.  Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study.

Authors:  Jing Wang; Zhengchuan Zhang; Feilong Deng
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

5.  Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study.

Authors:  Teh-Jing Mu; Dong-Won Lee; Kwang-Ho Park; Ik-Sang Moon
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614

6.  Fabrication of a screw-retained hybrid prosthesis following treatment of peri-implant defects: a case report.

Authors:  Bebek Serra Oguz Ahmet; Gulsum Sayin Ozel; Hilal Uslu Toygar
Journal:  J Istanb Univ Fac Dent       Date:  2016-10-01

Review 7.  Surface modification of biomedical and dental implants and the processes of inflammation, wound healing and bone formation.

Authors:  Clark M Stanford
Journal:  Int J Mol Sci       Date:  2010-01-25       Impact factor: 5.923

8.  Beneficial osseointegration effect of hydroxyapatite coating on cranial implant - FEM investigation.

Authors:  Jakub Chamrad; Petr Marcián; Jan Cizek
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

9.  A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

Authors:  Antoine N Berberi; Joseph M Sabbagh; Moustafa N Aboushelib; Ziad F Noujeim; Ziad A Salameh
Journal:  Front Physiol       Date:  2014-01-31       Impact factor: 4.566

10.  Effects of mechanical repetitive load on bone quality around implants in rat maxillae.

Authors:  Yusuke Uto; Shinichiro Kuroshima; Takayoshi Nakano; Takuya Ishimoto; Nao Inaba; Yusuke Uchida; Takashi Sawase
Journal:  PLoS One       Date:  2017-12-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.