Literature DB >> 26168173

Resolution and brightness characteristics of short-lag spatial coherence (SLSC) images.

Muyinatu A Lediju Bell, Jeremy J Dahl, Gregg E Trahey.   

Abstract

We previously described a novel beamforming method that images the spatial correlation of an echo wave field with demonstrated applications to clutter reduction in high-noise environments. In this paper, several characteristics of the resolution and brightness of short-lag spatial coherence (SLSC) images formed by this method are compared with B-mode images formed by conventional delay-and-sum beamforming methods. Point target widths were measured to estimate resolution, the autocorrelation of image texture was measured to estimate texture size, and the contrast (i.e., brightness ratio) of clinically relevant targets was assessed. SLSC images demonstrate improved resolution and contrast with increasing values of channel noise and clutter, whereas B-mode resolution was degraded in the presence of high noise (i.e., > -12 dB channel noise-to-signal ratios) and high clutter magnitudes (i.e., > -21 dB relative to point target magnitude). Lateral resolution in SLSC images was improved with increasing lag value, whereas axial resolution was degraded with increasing correlation kernel length. The texture size of SLSC images was smaller than that of matched B-mode images. Results demonstrate that the resolution and contrast of coherence-based images depend on a range of parameters, but are generally superior to those of matched B-mode images under challenging imaging conditions.

Entities:  

Mesh:

Year:  2015        PMID: 26168173      PMCID: PMC4821635          DOI: 10.1109/TUFFC.2014.006909

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  16 in total

Review 1.  Tissue harmonic imaging techniques: physical principles and clinical applications.

Authors:  T S Desser; R B Jeffrey
Journal:  Semin Ultrasound CT MR       Date:  2001-02       Impact factor: 1.875

2.  Capon beamforming in medical ultrasound imaging with focused beams.

Authors:  Francois Vignon; Michael R Burcher
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-03       Impact factor: 2.725

3.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  Eigenspace based minimum variance beamforming applied to ultrasound imaging of acoustically hard tissues.

Authors:  Saeed Mehdizadeh; Andreas Austeng; Tonni F Johansen; Sverre Holm
Journal:  IEEE Trans Med Imaging       Date:  2012-08-01       Impact factor: 10.048

5.  Transfer functions for describing ultrasound system performance.

Authors:  J C Gore; S Leeman
Journal:  Phys Med Biol       Date:  1979-01       Impact factor: 3.609

6.  Point spread-function, line spread-function, and modulation transfer function. Tools for the study of imaging systems.

Authors:  K Rossmann
Journal:  Radiology       Date:  1969-08       Impact factor: 11.105

7.  Short-lag spatial coherence of backscattered echoes: imaging characteristics.

Authors:  Muyinatu A Lediju; Gregg E Trahey; Brett C Byram; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-07       Impact factor: 2.725

8.  In vivo application of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound.

Authors:  Vaibhav Kakkad; Jeremy Dahl; Sarah Ellestad; Gregg Trahey
Journal:  Ultrason Imaging       Date:  2014-08-12       Impact factor: 1.578

9.  Lesion detectability in diagnostic ultrasound with short-lag spatial coherence imaging.

Authors:  Jeremy J Dahl; Dongwoon Hyun; Muyinatu Lediju; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2011-04       Impact factor: 1.578

10.  Quantitative assessment of the magnitude, impact and spatial extent of ultrasonic clutter.

Authors:  Muyinatu A Lediju; Michael J Pihl; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2008-07       Impact factor: 1.578

View more
  11 in total

1.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

2.  Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

Authors:  Dongwoon Hyun; Lotfi Abou-Elkacem; Valerie A Perez; Sayan Mullick Chowdhury; Juergen K Willmann; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2018-01       Impact factor: 10.048

3.  Robust Short-Lag Spatial Coherence Imaging.

Authors:  Arun Asokan Nair; Trac Duy Tran; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-03       Impact factor: 2.725

4.  Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging.

Authors:  Yuanguo Wang; Yadan Wang; Mingzhou Liu; Zhengfeng Lan; Chichao Zheng; Hu Peng
Journal:  Biomed Eng Online       Date:  2022-06-18       Impact factor: 3.903

Review 5.  Spatial Coherence in Medical Ultrasound: A Review.

Authors:  James Long; Gregg Trahey; Nick Bottenus
Journal:  Ultrasound Med Biol       Date:  2022-03-11       Impact factor: 3.694

6.  Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.

Authors:  Emelina P Vienneau; Kathryn A Ozgun; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

7.  Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging.

Authors:  Will Long; Dongwoon Hyun; Kingshuk Roy Choudhury; David Bradway; Patricia McNally; Brita Boyd; Sarah Ellestad; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2018-01-11       Impact factor: 2.998

8.  Iterative Model-Based Beamforming for High Dynamic Range Applications.

Authors:  Siegfried Schlunk; Kazuyuki Dei; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

9.  Real-Time In Vivo Imaging of Human Liver Vasculature Using Coherent Flow Power Doppler: A Pilot Clinical Study.

Authors:  You Leo Li; Dongwoon Hyun; Jessica Ducey-Wysling; Isabelle Durot; Aurelie D'Hondt; Bhavik Natvar Patel; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-08-27       Impact factor: 3.267

10.  GPU implementation of photoacoustic short-lag spatial coherence imaging for improved image-guided interventions.

Authors:  Eduardo A Gonzalez; Muyinatu A Lediju Bell
Journal:  J Biomed Opt       Date:  2020-07       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.