Literature DB >> 21768022

Short-lag spatial coherence of backscattered echoes: imaging characteristics.

Muyinatu A Lediju1, Gregg E Trahey, Brett C Byram, Jeremy J Dahl.   

Abstract

Conventional ultrasound images are formed by delay-and-sum beamforming of the backscattered echoes received by individual elements of the transducer aperture. Although the delay-and-sum beamformer is well suited for ultrasound image formation, it is corrupted by speckle noise and challenged by acoustic clutter and phase aberration. We propose an alternative method of imaging utilizing the short-lag spatial coherence (SLSC) of the backscattered echoes. Compared with matched B-mode images, SLSC images demonstrate superior SNR and contrast-to-noise ratio in simulated and experimental speckle-generating phantom targets, but are shown to be challenged by limited point target conspicuity. Matched B-mode and SLSC images of a human thyroid are presented. The challenges and opportunities of real-time implementation of SLSC imaging are discussed.

Entities:  

Mesh:

Year:  2011        PMID: 21768022      PMCID: PMC3172134          DOI: 10.1109/TUFFC.2011.1957

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  21 in total

1.  Real-time spatial compound imaging in breast ultrasound.

Authors:  Sabine Huber; Monika Wagner; Michael Medl; Heinrich Czembirek
Journal:  Ultrasound Med Biol       Date:  2002-02       Impact factor: 2.998

2.  Axial resolution in elastography.

Authors:  Raffaella Righetti; Jonathan Ophir; Periklis Ktonas
Journal:  Ultrasound Med Biol       Date:  2002-01       Impact factor: 2.998

3.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

4.  Spatial and temporal aberrator stability for real-time adaptive imaging.

Authors:  Jeremy J Dahl; Mary S Soo; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-09       Impact factor: 2.725

5.  Adaptive imaging and spatial compounding in the presence of aberration.

Authors:  Jeremy J Dahl; Drake A Guenther; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-07       Impact factor: 2.725

6.  Stationary clutter rejection in echocardiography.

Authors:  Gil Zwirn; Solange Akselrod
Journal:  Ultrasound Med Biol       Date:  2006-01       Impact factor: 2.998

7.  The application of k-space in pulse echo ultrasound.

Authors:  W F Walker; G E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

8.  Speckle coherence and implications for adaptive imaging.

Authors:  W F Walker; G E Trahey
Journal:  J Acoust Soc Am       Date:  1997-04       Impact factor: 1.840

9.  Phase aberration measurements in medical ultrasound: human studies.

Authors:  M O'Donnell; S W Flax
Journal:  Ultrason Imaging       Date:  1988-01       Impact factor: 1.578

10.  Acoustic radiation force impulse imaging for noninvasive characterization of carotid artery atherosclerotic plaques: a feasibility study.

Authors:  Jeremy J Dahl; Douglas M Dumont; Jason D Allen; Elizabeth M Miller; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2009-02-25       Impact factor: 2.998

View more
  89 in total

1.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

2.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.

Authors:  Muyinatu A Lediju Bell; Nathanael Kuo; Danny Y Song; Emad M Boctor
Journal:  Biomed Opt Express       Date:  2013-09-04       Impact factor: 3.732

3.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

5.  In vivo visualization of prostate brachytherapy seeds with photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Nathanael P Kuo; Danny Y Song; Jin U Kang; Emad M Boctor
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

6.  Equivalence of time and aperture domain additive noise in ultrasound coherence.

Authors:  Nick B Bottenus; Gregg E Trahey
Journal:  J Acoust Soc Am       Date:  2015-01       Impact factor: 1.840

7.  Pseudononlinear ultrasound simulation approach for reverberation clutter.

Authors:  Brett Byram; Jasmine Shu
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-08

8.  Additive noise models for photoacoustic spatial coherence theory.

Authors:  Brooke Stephanian; Michelle T Graham; Huayu Hou; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2018-10-18       Impact factor: 3.732

9.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

10.  Contrast in intracardiac acoustic radiation force impulse images of radiofrequency ablation lesions.

Authors:  Stephanie A Eyerly; Tristram D Bahnson; Jason I Koontz; David P Bradway; Douglas M Dumont; Gregg E Trahey; Patrick D Wolf
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.