In vivo application of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound.

Vaibhav Kakkad1, Jeremy Dahl2, Sarah Ellestad3, Gregg Trahey2.   

Abstract

Fetal scanning is one of the most common applications of ultrasound imaging and serves as a source of vital information about maternal and fetal health. Visualization of clinically relevant structures, however, can be severely compromised in difficult-to-image patients due to poor resolution and the presence of high levels of acoustical noise or clutter. We have developed novel coherence-based beamforming methods called Short-Lag Spatial Coherence (SLSC) imaging and Harmonic Spatial Coherence imaging (HSCI), and applied them to suppress the effects of clutter in fetal imaging. This method is used to create images of the spatial coherence of the backscattered ultrasound as opposed to images of echo magnitude. We present the results of a patient study to assess the benefits of coherence-based beamforming in the context of first trimester fetal exams. Matched fundamental B-mode, SLSC, harmonic B-mode, and HSCI images were generated using raw radio frequency data collected on 11 volunteers in the first trimester of pregnancy. The images were compared for qualitative differences in image texture and target conspicuity as well as using quantitative imaging metrics such as signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast. SLSC and HSCI showed statistically significant improvements across all imaging metrics compared with B-mode and harmonic B-mode, respectively. These improvements were greatest for poor quality B-mode images where contrast of anechoic targets was improved from 15 dB in fundamental B-mode to 27 dB in SLSC and 17 dB in harmonic B-mode to 30 dB in HSCI. CNR improved from 1.4 to 2.5 in the fundamental images and 1.4 to 3.1 in the harmonic case. These results exhibit the potential of coherence-based beamforming to improve image quality and target detectability, especially in high noise environments.
© The Author(s) 2014.

Entities:  

Keywords:  beamforming; clutter reduction; fetal ultrasound; spatial coherence; ultrasound imaging

Mesh:

Year:  2014        PMID: 25116292      PMCID: PMC4326611          DOI: 10.1177/0161734614547281

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  26 in total

1.  An ultrasound research interface for a clinical system.

Authors:  Mohammad Ashfaq; Shelby S Brunke; Jeremy J Dahl; Helmut Ermert; Christian Hansen; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-10       Impact factor: 2.725

Review 2.  A systematic review of the accuracy of first-trimester ultrasound examination for detecting major congenital heart disease.

Authors:  S V Rasiah; M Publicover; A K Ewer; K S Khan; M D Kilby; J Zamora
Journal:  Ultrasound Obstet Gynecol       Date:  2006-07       Impact factor: 7.299

3.  Maternal obesity: a potential source of error in sonographic prenatal diagnosis.

Authors:  H M Wolfe; R J Sokol; S M Martier; I E Zador
Journal:  Obstet Gynecol       Date:  1990-09       Impact factor: 7.661

4.  Elevated first-trimester nuchal translucency increases the risk of congenital heart defects.

Authors:  Ray O Bahado-Singh; Ronald Wapner; Elizabeth Thom; Julia Zachary; Lawrence Platt; Maurice J Mahoney; Anthony Johnson; Richard K Silver; Eugene Pergament; Karen Filkins; W Allen Hogge; R Douglas Wilson; Laird G Jackson
Journal:  Am J Obstet Gynecol       Date:  2005-05       Impact factor: 8.661

5.  Lesion detectability in diagnostic ultrasound with short-lag spatial coherence imaging.

Authors:  Jeremy J Dahl; Dongwoon Hyun; Muyinatu Lediju; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2011-04       Impact factor: 1.578

6.  Sources of image degradation in fundamental and harmonic ultrasound imaging: a nonlinear, full-wave, simulation study.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

7.  Clinical impact of first and early second trimester fetal echocardiography on high risk pregnancies.

Authors:  J S Carvalho; G Moscoso; A Tekay; S Campbell; B Thilaganathan; E A Shinebourne
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

8.  The impact of maternal obesity on satisfactory detailed anatomic ultrasound image acquisition.

Authors:  Fadi R Khoury; Hugh M Ehrenberg; Brian M Mercer
Journal:  J Matern Fetal Neonatal Med       Date:  2009-04

9.  Does advanced ultrasound equipment improve the adequacy of ultrasound visualization of fetal cardiac structures in the obese gravid woman?

Authors:  Israel Hendler; Sean C Blackwell; Marjorie C Treadwell; Emmanuel Bujold; Robert J Sokol; Yoram Sorokin
Journal:  Am J Obstet Gynecol       Date:  2004-06       Impact factor: 8.661

10.  The impact of maternal obesity on midtrimester sonographic visualization of fetal cardiac and craniospinal structures.

Authors:  I Hendler; S C Blackwell; E Bujold; M C Treadwell; H M Wolfe; R J Sokol; Y Sorokin
Journal:  Int J Obes Relat Metab Disord       Date:  2004-12
View more
  9 in total

1.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

2.  Improved Visualization in Difficult-to-Image Stress Echocardiography Patients Using Real-Time Harmonic Spatial Coherence Imaging.

Authors:  Dongwoon Hyun; Anna Lisa C Crowley; Melissa LeFevre; Jayne Cleve; Jarrett Rosenberg; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  MimickNet, Mimicking Clinical Image Post- Processing Under Black-Box Constraints.

Authors:  Ouwen Huang; Will Long; Nick Bottenus; Marcelo Lerendegui; Gregg E Trahey; Sina Farsiu; Mark L Palmeri
Journal:  IEEE Trans Med Imaging       Date:  2020-01-31       Impact factor: 10.048

4.  Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

Authors:  Dongwoon Hyun; Lotfi Abou-Elkacem; Valerie A Perez; Sayan Mullick Chowdhury; Juergen K Willmann; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2018-01       Impact factor: 10.048

5.  Resolution and brightness characteristics of short-lag spatial coherence (SLSC) images.

Authors:  Muyinatu A Lediju Bell; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

6.  Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging.

Authors:  Will Long; Dongwoon Hyun; Kingshuk Roy Choudhury; David Bradway; Patricia McNally; Brita Boyd; Sarah Ellestad; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2018-01-11       Impact factor: 2.998

7.  A reconfigurable all-optical ultrasound transducer array for 3D endoscopic imaging.

Authors:  Erwin J Alles; Nora Fook Sheung; Sacha Noimark; Edward Z Zhang; Paul C Beard; Adrien E Desjardins
Journal:  Sci Rep       Date:  2017-04-26       Impact factor: 4.379

8.  Lag-Based Filtered-Delay Multiply and Sum Beamformer Combined with Two Phase-Related Factors for Medical Ultrasound Imaging.

Authors:  Ke Song; Paul Liu; Dong C Liu
Journal:  Comput Math Methods Med       Date:  2020-08-28       Impact factor: 2.238

9.  CohereNet: A Deep Learning Architecture for Ultrasound Spatial Correlation Estimation and Coherence-Based Beamforming.

Authors:  Alycen Wiacek; Eduardo Gonzalez; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.