Literature DB >> 20443510

Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation.

M J van der Bom1, L W Bartels, M J Gounis, R Homan, J Timmer, M A Viergever, J P W Pluim.   

Abstract

PURPOSE: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range.
METHODS: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure.
RESULTS: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively.
CONCLUSIONS: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.

Mesh:

Year:  2010        PMID: 20443510     DOI: 10.1118/1.3366252

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Fully automatic initialization of two-dimensional-three-dimensional medical image registration using hybrid classifier.

Authors:  Jing Wu; Emam E Abdel Fatah; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-02

2.  Mouse atlas registration with non-tomographic imaging modalities-a pilot study based on simulation.

Authors:  Hongkai Wang; David B Stout; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2012-08       Impact factor: 3.488

3.  A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm.

Authors:  A Duménil; A Kaladji; M Castro; C Göksu; A Lucas; P Haigron
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-26       Impact factor: 2.924

4.  Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration.

Authors:  Javad Fotouhi; Bernhard Fuerst; Alex Johnson; Sing Chun Lee; Russell Taylor; Greg Osgood; Nassir Navab; Mehran Armand
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-19       Impact factor: 2.924

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.