An automatic 2D-3D image matching method for reproducing spatial knee joint positions using single or dual fluoroscopic images.

Zhonglin Zhu1, Guoan Li.   

Abstract

Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D-3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.

Entities:  

Mesh:

Year:  2011        PMID: 21806411      PMCID: PMC3740401          DOI: 10.1080/10255842.2011.597387

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  18 in total

1.  A model-based method for the reconstruction of total knee replacement kinematics.

Authors:  S Zuffi; A Leardini; F Catani; S Fantozzi; A Cappello
Journal:  IEEE Trans Med Imaging       Date:  1999-10       Impact factor: 10.048

2.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

3.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  IEEE Trans Med Imaging       Date:  2003-12       Impact factor: 10.048

4.  Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions.

Authors:  Izumi Kanisawa; Anne Z Banks; Scott A Banks; Hideshige Moriya; Akihiro Tsuchiya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-12-18       Impact factor: 4.342

5.  Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics.

Authors:  Guoan Li; Thomas H Wuerz; Louis E DeFrate
Journal:  J Biomech Eng       Date:  2004-04       Impact factor: 2.097

6.  Non-invasive determination of coupled motion of the scapula and humerus--an in-vitro validation.

Authors:  Daniel F Massimini; Jon J P Warner; Guoan Li
Journal:  J Biomech       Date:  2010-11-04       Impact factor: 2.712

7.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system.

Authors:  Jeffrey Bingham; Guoan Li
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

8.  Measurement of vertebral kinematics using noninvasive image matching method-validation and application.

Authors:  Shaobai Wang; Peter Passias; Gang Li; Guoan Li; Kirkham Wood
Journal:  Spine (Phila Pa 1976)       Date:  2008-05-15       Impact factor: 3.468

9.  New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy.

Authors:  Jennifer M Scarvell; Mark R Pickering; Paul N Smith
Journal:  J Orthop Res       Date:  2010-03       Impact factor: 3.494

10.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

View more
  14 in total

1.  Prediction of in vivo knee joint kinematics using a combined dual fluoroscopy imaging and statistical shape modeling technique.

Authors:  Jing-Sheng Li; Tsung-Yuan Tsai; Shaobai Wang; Pingyue Li; Young-Min Kwon; Andrew Freiberg; Harry E Rubash; Guoan Li
Journal:  J Biomech Eng       Date:  2014-12       Impact factor: 2.097

2.  Fully automatic initialization of two-dimensional-three-dimensional medical image registration using hybrid classifier.

Authors:  Jing Wu; Emam E Abdel Fatah; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-02

Review 3.  Functional knee assessment with advanced imaging.

Authors:  Keiko Amano; Qi Li; C Benjamin Ma
Journal:  Curr Rev Musculoskelet Med       Date:  2016-06

4.  Gaussian mixture models based 2D-3D registration of bone shapes for orthopedic surgery planning.

Authors:  Marta Valenti; Giancarlo Ferrigno; Dario Martina; Weimin Yu; Guoyan Zheng; Mohsen Akbari Shandiz; Carolyn Anglin; Elena De Momi
Journal:  Med Biol Eng Comput       Date:  2016-03-23       Impact factor: 2.602

5.  Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

Authors:  M Berger; K Müller; A Aichert; M Unberath; J Thies; J-H Choi; R Fahrig; A Maier
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

6.  Statistical shape modeling predicts patellar bone geometry to enable stereo-radiographic kinematic tracking.

Authors:  Lowell M Smoger; Kevin B Shelburne; Adam J Cyr; Paul J Rullkoetter; Peter J Laz
Journal:  J Biomech       Date:  2017-05-17       Impact factor: 2.712

Review 7.  Anterior cruciate ligament reconstruction related complications: 2D and 3D high-resolution magnetic resonance imaging evaluation.

Authors:  Uma Thakur; Vaibhav Gulati; Jay Shah; David Tietze; Avneesh Chhabra
Journal:  Skeletal Radiol       Date:  2022-01-03       Impact factor: 2.199

8.  In-vivo analysis of flexion axes of the knee: Femoral condylar motion during dynamic knee flexion.

Authors:  Yong Feng; Tsung-Yuan Tsai; Jing-Sheng Li; Harry E Rubash; Guoan Li; Andrew Freiberg
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-12-24       Impact factor: 2.063

9.  An in-vitro biomechanical study of different fixation techniques for the extended trochanteric osteotomy in revision THA.

Authors:  Zhonglin Zhu; Hui Ding; Hongyi Shao; Yixin Zhou; Guangzhi Wang
Journal:  J Orthop Surg Res       Date:  2013-04-09       Impact factor: 2.359

10.  Three-dimensional motions of distal syndesmosis during walking.

Authors:  Chen Wang; Junsheng Yang; Shaobai Wang; Xin Ma; Xu Wang; Jiazhang Huang; Chao Zhang; Li Chen; Jian Xu; Xiang Geng; Kan Wang
Journal:  J Orthop Surg Res       Date:  2015-10-24       Impact factor: 2.359

View more