Literature DB >> 26148865

Imaging dose from cone beam computed tomography in radiation therapy.

Parham Alaei1, Emiliano Spezi2.   

Abstract

Imaging dose in radiation therapy has traditionally been ignored due to its low magnitude and frequency in comparison to therapeutic dose used to treat patients. The advent of modern, volumetric, imaging modalities, often as an integral part of linear accelerators, has facilitated the implementation of image-guided radiation therapy (IGRT), which is often accomplished by daily imaging of patients. Daily imaging results in additional dose delivered to patient that warrants new attention be given to imaging dose. This review summarizes the imaging dose delivered to patients as the result of cone beam computed tomography (CBCT) imaging performed in radiation therapy using current methods and equipment. This review also summarizes methods to calculate the imaging dose, including the use of Monte Carlo (MC) and treatment planning systems (TPS). Peripheral dose from CBCT imaging, dose reduction methods, the use of effective dose in describing imaging dose, and the measurement of CT dose index (CTDI) in CBCT systems are also reviewed.
Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cone beam CT; Imaging dose; MV CBCT; kV CBCT

Mesh:

Year:  2015        PMID: 26148865     DOI: 10.1016/j.ejmp.2015.06.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  25 in total

1.  Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

Authors:  Mariana Baptista; Salvatore Di Maria; Sandra Vieira; Joana Santos; Joana Pereira; Miguel Pereira; Pedro Vaz
Journal:  Radiat Environ Biophys       Date:  2018-11-03       Impact factor: 1.925

2.  Volumetric image-guided highly conformal radiotherapy of the prostate bed: Toxicity analysis.

Authors:  Gianluca Ingrosso; Alessandra Carosi; Daniela di Cristino; Elisabetta Ponti; Andrea Lancia; Alessandra Murgia; Claudia Bruni; Pasquale Morelli; Franca Pietrasanta; Riccardo Santoni
Journal:  Rep Pract Oncol Radiother       Date:  2016-11-24

3.  Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.

Authors:  Yue-Houng Hu; Joerg Rottmann; Rony Fueglistaller; Marios Myronakis; Adam Wang; Pascal Huber; Daniel Shedlock; Daniel Morf; Paul Baturin; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

4.  PCXMC cone beam computed tomography dosimetry investigations.

Authors:  Aaron Fetin; Lucy Cartwright; Jonathan Sykes; Alicja Wach
Journal:  Phys Eng Sci Med       Date:  2022-01-24

5.  Extended localization and adaptive dose calculation using HU corrected cone beam CT: Phantom study.

Authors:  K Mohamathu Rafic; S Amalan; B S Timothy Peace; B Paul Ravindran
Journal:  Rep Pract Oncol Radiother       Date:  2018-02-24

6.  Superior Postimplant Dosimetry Achieved Using Dynamic Intraoperative Dosimetry for Permanent Prostate Brachytherapy.

Authors:  Tanmay Singh; Junghoon Lee; Marianna Zahurak; Hee Joon Bae; Tamey Habtu; Robert Hobbs; Yi Le; Everette C Burdette; Daniel Y Song
Journal:  Pract Radiat Oncol       Date:  2021-03-13

7.  Influence of daily imaging on plan quality and normal tissue toxicity for prostate cancer radiotherapy.

Authors:  Katharina Bell; Marina Heitfeld; Norbert Licht; Christian Rübe; Yvonne Dzierma
Journal:  Radiat Oncol       Date:  2017-01-10       Impact factor: 3.481

8.  Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies.

Authors:  Jarryd G Buckley; Dean Wilkinson; Alessandra Malaroda; Peter Metcalfe
Journal:  J Appl Clin Med Phys       Date:  2017-12-19       Impact factor: 2.102

9.  Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging.

Authors:  Kihong Son; Jieun Chang; Hoyeon Lee; Changhwan Kim; Taewon Lee; Seungryong Cho; Sohyun Park; Jin Sung Kim
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

10.  A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

Authors:  Kuo Men; Jianrong Dai
Journal:  Technol Cancer Res Treat       Date:  2017-11-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.