Literature DB >> 35072895

PCXMC cone beam computed tomography dosimetry investigations.

Aaron Fetin1,2, Lucy Cartwright3, Jonathan Sykes4, Alicja Wach3.   

Abstract

With cone beam computed tomography (CBCT) in image guided radiation therapy being amongst the most widely used imaging modalities, there has been an increasing interest in quantifying the concomitant dose and risk. Whilst there have been several studies on this topic, there remains a lack of standardisation and knowledge on dose variations and the impact of patient size. Recently, PCXMC (a Monte Carlo simulator) has been used to assess both the concomitant dose and dosimetric impact of patient size variations for CBCT. The scopes of these studies, however, have included only a limited range of imaging manufacturers, protocols, and patient sizes. An approach using PCXMC and MATLAB was developed to enable a generalised method for rapidly quantifying and formulating the concomitant dose as a function of patient size across numerous CBCT vendors and protocols. The method was investigated using the Varian on board imaging 1.6 default pelvis and pelvis spotlight protocols, for 94 adult and paediatric phantoms over 6 age groups with extensive height and mass variations. It was found that dose varies significantly with patient size, as much as doubling and halving the average for patients of lower and higher mass, respectively. These variations, however, can be formulated and accounted for using the method developed, across a wide range of patient sizes for all CBCT vendors and protocols. This will enable the development of a comprehensive catalogue to account for concomitant doses in almost any clinically relevant scenario.
© 2022. Australasian College of Physical Scientists and Engineers in Medicine.

Entities:  

Keywords:  CBCT; Dosimetry; IGRT; OBI; PCXMC; Radiotherapy

Mesh:

Year:  2022        PMID: 35072895     DOI: 10.1007/s13246-022-01103-9

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  21 in total

1.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

2.  Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report).

Authors:  Hugo de Las Heras Gala; Alberto Torresin; Alexandru Dasu; Osvaldo Rampado; Harry Delis; Irene Hernández Girón; Chrysoula Theodorakou; Jonas Andersson; John Holroyd; Mats Nilsson; Sue Edyvean; Vesna Gershan; Lama Hadid-Beurrier; Christopher Hoog; Gregory Delpon; Ismael Sancho Kolster; Primož Peterlin; Julia Garayoa Roca; Paola Caprile; Costas Zervides
Journal:  Phys Med       Date:  2017-06-09       Impact factor: 2.685

3.  Image Guided Radiation Therapy (IGRT) Practice Patterns and IGRT's Impact on Workflow and Treatment Planning: Results From a National Survey of American Society for Radiation Oncology Members.

Authors:  Nima Nabavizadeh; David A Elliott; Yiyi Chen; Aaron S Kusano; Timur Mitin; Charles R Thomas; John M Holland
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-03-15       Impact factor: 7.038

4.  National survey on image-guided radiotherapy practice in New Zealand.

Authors:  Jerusha Padayachee; Jasmin Loh; Albert Tiong; Louis Lao
Journal:  J Med Imaging Radiat Oncol       Date:  2017-10-26       Impact factor: 1.735

Review 5.  Imaging dose from cone beam computed tomography in radiation therapy.

Authors:  Parham Alaei; Emiliano Spezi
Journal:  Phys Med       Date:  2015-07-04       Impact factor: 2.685

Review 6.  Image-guided radiotherapy: a new dimension in radiation oncology.

Authors:  Florian Sterzing; Rita Engenhart-Cabillic; Michael Flentje; Jürgen Debus
Journal:  Dtsch Arztebl Int       Date:  2011-04-22       Impact factor: 5.594

7.  ACR-ASTRO Practice Parameter for Image-guided Radiation Therapy (IGRT).

Authors:  Join Y Luh; Kevin V Albuquerque; Cheewai Cheng; Ralph P Ermoian; Nima Nabavizadeh; Homayon Parsai; John C Roeske; Stephanie E Weiss; Raymond B Wynn; Yan Yu; Seth A Rosenthal; Alan Hartford
Journal:  Am J Clin Oncol       Date:  2020-07       Impact factor: 2.339

8.  Survey of image-guided radiotherapy use in Australia.

Authors:  Vikneswary Batumalai; Lois Charlotte Holloway; Shivani Kumar; Kylie Dundas; Michael Geoffrey Jameson; Shalini Kavita Vinod; Geoff P Delaney
Journal:  J Med Imaging Radiat Oncol       Date:  2016-11-09       Impact factor: 1.735

9.  Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129.

Authors:  M M Rehani; R Gupta; S Bartling; G C Sharp; R Pauwels; T Berris; J M Boone
Journal:  Ann ICRP       Date:  2015-07

10.  Measurements of the dose delivered during CT exams using AAPM Task Group Report No. 111.

Authors:  Caroline Descamps; Mercedes Gonzalez; Edgardo Garrigo; Alejandro Germanier; Daniel Venencia
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.