Literature DB >> 26133986

Performance analysis of a dedicated breast MR-HIFU system for tumor ablation in breast cancer patients.

R Deckers1, L G Merckel, B Denis de Senneville, G Schubert, M Köhler, F M Knuttel, W P Th M Mali, C T W Moonen, M A A J van den Bosch, L W Bartels.   

Abstract

MR-guided HIFU ablation is a promising technique for the non-invasive treatment of breast cancer. A phase I study was performed to assess the safety and treatment accuracy and precision of MR-HIFU ablation in breast cancer patients (n=10) using a newly developed MR-HIFU platform dedicated to applications in the breast. In this paper a technical analysis of the performance of the dedicated breast MR-HIFU system during breast tumors ablation is described. The main points of investigation were the spatial targeting accuracy and precision of the system and the performance of real-time respiration-corrected MR thermometry.The mean targeting accuracy was in the range of 2.4-2.6 mm, whereas the mean targeting precision was in the range of 1.5-1.8 mm. To correct for respiration-induced magnetic field fluctuations during MR temperature mapping a look-up-table (LUT)-based correction method was used. An optimized procedural sedation protocol in combination with the LUT-based correction method allowed for precise MR thermometry during the ablation procedure (temperature standard deviation <3 °C). No unwanted heating in the near field (i.e. skin) nor in the far field (pectoral muscle) was detected.The newly developed dedicated breast MR-HIFU system allows for safe, accurate and precise ablation of breast tumors.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26133986     DOI: 10.1088/0031-9155/60/14/5527

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Multi-echo MR thermometry using iterative separation of baseline water and fat images.

Authors:  Megan E Poorman; Ieva Braškutė; Lambertus W Bartels; William A Grissom
Journal:  Magn Reson Med       Date:  2018-11-05       Impact factor: 4.668

2.  Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging.

Authors:  Yuhong Peng; Chao Zou; Yangzi Qiao; Changjun Tie; Qian Wan; Rui Jiang; Chuanli Cheng; Dong Liang; Hairong Zheng; Faqi Li; Xin Liu
Journal:  MAGMA       Date:  2018-06-14       Impact factor: 2.310

3.  Novel acoustic coupling bath using magnetite nanoparticles for MR-guided transcranial focused ultrasound surgery.

Authors:  Steven P Allen; Tom Steeves; Austin Fergusson; Dave Moore; Richey M Davis; Eli Vlaisialjevich; Craig H Meyer
Journal:  Med Phys       Date:  2019-10-29       Impact factor: 4.071

4.  Simultaneous MR thermometry and acoustic radiation force imaging using interleaved acquisition.

Authors:  Joshua T de Bever; Henrik Odéen; Lorne W Hofstetter; Dennis L Parker
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

5.  Enhanced efficacy of combination heat shock targeted polymer therapeutics with high intensity focused ultrasound.

Authors:  Nick Frazier; Allison Payne; Christopher Dillon; Nithya Subrahmanyam; Hamidreza Ghandehari
Journal:  Nanomedicine       Date:  2016-11-29       Impact factor: 5.307

6.  Phase aberration simulation study of MRgFUS breast treatments.

Authors:  Alexis I Farrer; Scott Almquist; Christopher R Dillon; Leigh A Neumayer; Dennis L Parker; Douglas A Christensen; Allison Payne
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

7.  A Breast-Specific MR Guided Focused Ultrasound Platform and Treatment Protocol: First-in-Human Technical Evaluation.

Authors:  Allison Payne; Robb Merrill; Emilee Minalga; J Rock Hadley; Henrik Odeen; Lorne W Hofstetter; Sara Johnson; Christine Tunon de Lara; Sophie Auriol; Stephanie Recco; Erik Dumont; Dennis L Parker; Jean Palussiere
Journal:  IEEE Trans Biomed Eng       Date:  2021-02-19       Impact factor: 4.538

8.  A preclinical study of diffusion-weighted MRI contrast as an early indicator of thermal ablation.

Authors:  Steven P Allen; Francesco Prada; Zhiyuan Xu; Jeremy Gatesman; Xue Feng; Helen Sporkin; Yekaterina Gilbo; Sydney DeCleene; Kim Butts Pauly; Craig H Meyer
Journal:  Magn Reson Med       Date:  2020-11-11       Impact factor: 3.737

9.  First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation.

Authors:  Laura G Merckel; Floor M Knuttel; Roel Deckers; Thijs van Dalen; Gerald Schubert; Nicky H G M Peters; Teun Weits; Paul J van Diest; Willem P Th M Mali; Paul H H B Vaessen; Joost M H H van Gorp; Chrit T W Moonen; Lambertus W Bartels; Maurice A A J van den Bosch
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

10.  Comparison of passive and scanning irradiation methods for carbon-ion radiotherapy for breast cancer.

Authors:  Hiroaki Matsubara; Kumiko Karasawa; Wataru Furuichi; Mitsuji Wakaisami; Shintaro Shiba; Masaru Wakatsuki; Tokuhiko Omatsu; Taku Inaniwa; Shigekazu Fukuda; Tadashi Kamada
Journal:  J Radiat Res       Date:  2018-09-01       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.