Literature DB >> 20307246

Flat-detector computed tomography with intravenous contrast material application in experimental aneurysms: comparison with multislice CT and conventional angiography.

Tobias Struffert1, Marc Doelken, Edyta Adamek, Marc Schwarz, Tobias Engelhorn, Stephan Kloska, Sabine Ott, Arnd Doerfler.   

Abstract

BACKGROUND: Despite limited soft tissue resolution flat-detector computed tomography (FD-CT) provides substantial superior spatial resolution in comparison with multislice computed tomography (MS-CT). This may add value in the visualization of small vascular structures if intravenous contrast application leads to substantial opacification and visibility of intracranial vessels or aneurysms.
PURPOSE: To evaluate the feasibility of visualization of vascular structures by FD-CT angiography (FD-CTA) after intravenous contrast injection compared with MS-CTA and intra-arterial digital subtracted angiography (IADSA) in an animal model.
MATERIAL AND METHODS: Aneurysms were created in the right common carotid artery in six New Zealand White Rabbits using the elastase technique. Imaging was performed using FD-CTA, MS-CTA (injection of 1 ml/kg body weight) and IADSA. Anonymized volume rendering reconstruction (VRT), maximum intensity projection (MIP), and multiplanar reconstruction (MPR) images were reconstructed and evaluated by two experienced reviewers for aneurysm geometry and vascular structure anatomy using standard tools of a dedicated workstation.
RESULTS: Aneurysms could be successfully created in all animals. Measurements of aneurysm geometry (aneurysm height, width, neck width) and vascular structures (brachiocephalic trunk, carotid artery diameter and plane) were nearly identical in all three modalities. Intra- and inter-observer correlations of the different parameters showed high r values between 0.83 and 0.99.
CONCLUSION: Our results show the feasibility of FD-CTA in comparison with MS-CTA and IADSA in an animal model. Despite limited soft tissue resolution, opacification of vascular structures with sufficient contrast to the surrounding structures was possible in all animals. Vascular structures appeared better delineated in FD-CTA than in MS-CTA, probably due to the superior spatial resolution.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307246     DOI: 10.3109/02841851003660073

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  8 in total

1.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results.

Authors:  Tobias Struffert; Stephan Kloska; Tobias Engelhorn; Yu Deuerling-Zheng; Sabine Ott; Marc Doelken; Marc Saake; Martin Köhrmann; Arnd Doerfler
Journal:  Eur Radiol       Date:  2010-08-14       Impact factor: 5.315

Review 2.  From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment.

Authors:  Waleed Brinjikji; Yong H Ding; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2015-04-22       Impact factor: 5.836

3.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model.

Authors:  Tobias Struffert; Sabine Ott; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Yu Deuerling-Zheng; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

4.  Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms.

Authors:  P Gölitz; T Struffert; F Knossalla; M Saake; S Ott; O Ganslandt; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

5.  Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.

Authors:  Julie Rösch; Stefan Lang; Philipp Gölitz; Bernd Kallmünzer; Karl Rössler; Arnd Doerfler; Tobias Struffert
Journal:  Clin Neuroradiol       Date:  2017-05-05       Impact factor: 3.649

6.  Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

Authors:  Sabine Ott; Philipp Gölitz; Edyta Adamek; Kevin Royalty; Arnd Doerfler; Tobias Struffert
Journal:  Interv Neuroradiol       Date:  2015-06-25       Impact factor: 1.610

7.  Intravenous contrast media application using cone-beam computed tomography in a rabbit model.

Authors:  Min-Sung Kim; Bok-Yeol Kim; Hwa-Young Choi; Yoon-Joo Choi; Song-Hee Oh; Ju-Hee Kang; Sae-Rom Lee; Ju-Han Kang; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang
Journal:  Imaging Sci Dent       Date:  2015-03-13

8.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.